Key Specifications
GTIN:4055626765778
Orderkey:1072838
(General):Ethernet/Ethernet 500 V AC 50 Hz 1 min.
Catalog page:Page 163 (C-6-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626765778
Orderkey1072838
(General)Ethernet/Ethernet 500 V AC 50 Hz 1 min.
Catalog pagePage 163 (C-6-2019)
Depth (Note)99 mm
Packing unit1 pc
Width (Note)45 mm
(Interfaces)Short-circuit protection for the sensor supply
Height (Note)114.5 mm
(Digital inputs)Short-circuit protection for the sensor supply
(IO-Link inputs)Short-circuit protection
Country of originUS (United States)
ETIM 5.0 (eCl@ss)EC001604
ETIM 6.0 (eCl@ss)EC001604
ETIM 7.0 (eCl@ss)EC001604
(Digital outputs)max. 200 mA (at L+/L-)
Custom tariff number85176200
Test section (General)24 V supply/Ethernet 500 V AC 50 Hz 1 min.
(Electrical isolation)pass
Input name (Interfaces)Digital inputs
Input frequency (Interfaces)0.5 kHz
eCl@ss 8.0 (Classifications)27242608
eCl@ss 9.0 (Classifications)27242608
Number of inputs (Interfaces)max. 8 (EN 61131-2 types 1 and 3)
Connection method (Interfaces)Push-in / plug connection
Protective circuit (Interfaces)Overload protection
Type of protection (Interfaces)Overload protection
Designation (Ambient conditions)PROFINET
Number of ports (Digital inputs)8
Degree of protection (Dimensions)IP20
Total sensor current (Interfaces)max. 1.6 A (from L+/L-)
Connection method (Digital inputs)Push-in / plug connection
Connection method (IO-Link inputs)Push-in / plug connection
Connection technology (Interfaces)3-wire
Number of outputs (IO-Link inputs)max. 8
Color (Supply of the IO-Link ports)gray
Output description (IO-Link inputs)IO-Link ports in digital output (DO) mode
Type of protection (Digital inputs)Overload protection
Type of protection (IO-Link inputs)Overload protection
No. of channels (Ambient conditions)2
Nominal load, ohmic (IO-Link inputs)4.8 W (120 Ω, at nominal load)
Type of protection (Digital outputs)Overload protection
Weight per Piece (excluding packing)0.010 g
Description of the input (Interfaces)IO-Link ports in digital input (DI) mode
Total sensor current (Digital inputs)max. 1.6 A (from L+/L-)
Connection method (Ambient conditions)RJ45 socket
Connection technology (Digital inputs)3-wire
Connection technology (IO-Link inputs)3-wire
Nominal input current (Digital inputs)typ. 3.5 mA
Nominal input voltage UIN (Interfaces)24 V DC
Behavior with overload (IO-Link inputs)Shutdown with automatic restart
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 1g
Nominal output voltage (IO-Link inputs)24 V DC
Sensor current per channel (Interfaces)max. 200 mA (from L+/L-)
Transmission speed (Ambient conditions)10/100 Mbps (with auto negotiation)
Net weight (Supply of the IO-Link ports)366.7 g
Description of the input (Digital inputs)Digital inputs (DI)
Nominal input current at UIN (Interfaces)typ. 3.5 mA
Transmission physics (Ambient conditions)Ethernet in RJ45 twisted pair
Nominal input voltage UIN (Digital inputs)24 V DC
Permissible cable length (Digital outputs)< 20 m
Input voltage range "0" signal (Interfaces)8 V DC ... 11.5 V DC (for C/Q pin)
Input voltage range "1" signal (Interfaces)10.5 V DC ... 13 V DC
Mounting type (Supply of the IO-Link ports)DIN rail
Sensor current per channel (Digital inputs)max. 200 mA (from L+/L-)
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Permissible humidity (operation) (Dimensions)10 % ... 95 %
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Housing material (Supply of the IO-Link ports)Polyamide
Input voltage range "0" signal (Digital inputs)5.2 V DC ... 6.4 V DC
Input voltage range "1" signal (Digital inputs)6.8 V DC ... 8 V DC
Nominal voltage for I/O supply (Digital outputs)24 V DC
Output current when switched off (IO-Link inputs)max. 400 µA
Output voltage when switched off (IO-Link inputs)max. 1 V
Maximum output current per device (IO-Link inputs)1.6 A
Maximum output current per channel (IO-Link inputs)200 mA
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 85 °C
Permissible humidity (storage/transport) (Dimensions)10 % ... 95 %
Nominal current for every IO-Link port (Digital outputs)max. 200 mA (at C/Q)

Product Description

The eight-channel IO-Link master offers convenient configuration of IO-Link devices via web-based management. It enables connectivity with PROFINET IO, MODBUS and OPC UA networks. It has eight additio
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top