| Parameter | Value |
|---|---|
| GTIN | 4017918144180 |
| Orderkey | 1857948 |
| Catalog page | Page 196 (C-1-2013) |
| Packing unit | 50 pc |
| Country of origin | PL (Poland) |
| (Connection data) | CUL |
| Custom tariff number | 85366990 |
| Screw thread (Dimensions) | M2 |
| Pitch (Key Commercial Data) | 3.81 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Stripping length (Dimensions) | 7 mm |
| Connection method (Dimensions) | Screw connection with tension sleeve |
| Range of articles (Dimensions) | IMC 1,5/..-ST |
| Nominal current IN (Dimensions) | 8 A |
| Insulating material (Dimensions) | PA |
| Number of positions (Dimensions) | 8 |
| Dimension a (Key Commercial Data) | 26.67 mm |
| Maximum load current (Dimensions) | 8 A (with 1.5 mm² conductor cross section) |
| Rated voltage (II/2) (Dimensions) | 320 V |
| Width [ w ] (Key Commercial Data) | 31.27 mm |
| Height [ h ] (Key Commercial Data) | 11.1 mm |
| Length [ l ] (Key Commercial Data) | 18.45 mm |
| Nominal cross section (Dimensions) | 1.5 mm² |
| Rated voltage (III/2) (Dimensions) | 160 V |
| Rated voltage (III/3) (Dimensions) | 160 V |
| Tightening torque max (Dimensions) | 0.25 Nm |
| Tightening torque, min (Dimensions) | 0.22 Nm |
| Weight per Piece (excluding packing) | 6.720 g |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Insulating material group (Dimensions) | I |
| Internal cylindrical gage (Dimensions) | A1 |
| Rated surge voltage (II/2) (Dimensions) | 2.5 kV |
| Rated surge voltage (III/2) (Dimensions) | 2.5 kV |
| Rated surge voltage (III/3) (Dimensions) | 2.5 kV |
| Maximum AWG according to UL/CUL (General) | 14 |
| Minimum AWG according to UL/CUL (General) | 30 |
| Conductor cross section AWG max. (General) | 16 |
| Conductor cross section AWG min. (General) | 28 |
| Conductor cross section solid max. (General) | 1.5 mm² |
| Conductor cross section solid min. (General) | 0.14 mm² |
| Connection in acc. with standard (Dimensions) | EN-VDE |
| Conductor cross section flexible max. (General) | 1.5 mm² |
| Conductor cross section flexible min. (General) | 0.14 mm² |
| Connection in acc. with standard (Connection data) | EN-VDE |
| Flammability rating according to UL 94 (Dimensions) | V0 |
| Flammability rating according to UL 94 (Connection data) | V0 |
| 2 conductors with same cross section, solid max. (General) | 0.5 mm² |
| 2 conductors with same cross section, solid min. (General) | 0.08 mm² |
| 2 conductors with same cross section, stranded max. (General) | 0.75 mm² |
| 2 conductors with same cross section, stranded min. (General) | 0.08 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (General) | 0.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (General) | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (General) | 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (General) | 0.25 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (General) | 0.34 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (General) | 0.2 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (General) | 0.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (General) | 0.5 mm² |
Technical specifications and performance data