Service time: Monday to Friday 9:00-18:00
ILC 200 UNI-PAC - ILC 200 UNI-PAC 2862291 PHOENIX CONTACT Controller
In Stock Hot Product

ILC 200 UNI-PAC

ILC 200 UNI-PAC 2862291 PHOENIX CONTACT Controller

$0.00USD
3764 in stock
Key Specifications
GTIN:4017918909116
Orderkey:2862291
Catalog page:Page 27 (AX-2009)
Depth (Note):71.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918909116
Orderkey2862291
Catalog pagePage 27 (AX-2009)
Depth (Note)71.5 mm
Packing unit1 pc
Width (Note)73 mm
Height (Note)140.5 mm
(Power supply)192 Bit (INTERBUS-Slave)
Country of originDE (Germany)
(Data interfaces)Analog supply (24 V DC) = 0.5 A
Shock (Dimensions)25g, Criterion 1, according to IEC 60068-2-27
Custom tariff number85371091
Weight (Control system)260 g
Mass storage (Direct I/Os)330 kByte
Number (Mechanical design)1
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Program memory (Direct I/Os)typ. 384 kByte (32 K instructions (IL))
Realtime clock (Direct I/Os)Integrated (battery backup)
Interface (Mechanical design)Parameterization/operation/diagnostics
Engineering tool (Direct I/Os)PC WORX
Input name (Fieldbus function)Digital inputs
Output name (Fieldbus function)Digital outputs
Shock (IEC 61131 runtime system)25g, Criterion 1, according to IEC 60068-2-27
Supply voltage (Data interfaces)7.5 V DC (the power supply comes from the upstream bus coupler)
Degree of protection (Dimensions)IP20
Residual ripple (Data interfaces)±5 %
Vibration (operation) (Dimensions)2g, criterion 1 according to IEC 60068-2-6
Input frequency (Fieldbus function)40 kHz
Limit frequency (Fieldbus function)20 kHz
Power dissipation (Data interfaces)max. 1.875 W
Diagnostics display (Control system)No
Number of inputs (Fieldbus function)4
Retentive mass storage (Direct I/Os)8 kByte (NVRAM)
Weight per Piece (excluding packing)366.300 g
Air pressure (operation) (Dimensions)70 kPa ... 108 kPa (up to 3000 m above sea level)
Amount of process data (Power supply)max. 4096 Bit (INTERBUS-Master)
Connection method (Fieldbus function)Spring-cage connection
Connection method (Mechanical design)6-pos. MINI DIN socket (PS/2)
Diagnostics tool (Ambient conditions)DIAG+ from version 1.14
Engineering tool (Ambient conditions)PC WORX
Number of control tasks (Direct I/Os)8
Number of outputs (Fieldbus function)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Controller redundancy (Control system)No
REACh SVHC (Standards and Regulations)1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
Supply voltage range (Data interfaces)19.2 V DC ... 30 V DC
Transmission speed (Mechanical design)19200 Baud
Number of parameter data (Power supply)max. 8 Byte (configurable)
Connection technology (Fieldbus function)2, 3, 4-wire
Number of supported devices (Power supply)max. 512
Ambient temperature (operation) (Dimensions)-25 °C ... 55 °C
Description of the input (Fieldbus function)Interrupt input, fast counter, pulse generator
Air pressure (storage/transport) (Dimensions)66 kPa ... 108 kPa (up to 3500 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 85 % (non-condensing)
Typical current consumption (Data interfaces)250 mA (no local bus device connected during idling, bus inactive)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Vibration (operation) (IEC 61131 runtime system)2g, criterion 1 according to IEC 60068-2-6
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 75 °C
Number of pulse direction outputs (Fieldbus function)2
Permissible humidity (storage/transport) (Dimensions)5 % ... 85 % (non-condensing)
Maximum output current per channel (Fieldbus function)500 mA
Number of devices with parameter channel (Power supply)max. 62
Vibration (storage/transport) (IEC 61131 runtime system)2g, criterion 1 according to IEC 60068-2-6
Connection in acc. with standard (IEC 61131 runtime system)CUL
Number of local bus devices that can be connected (Power supply)max. 63 (observe current consumption)
Number of supported branch terminals with remote bus branch (Power supply)max. 15
Max. total permissible current consumption of all I/O terminal blocks (Data interfaces)Communications power (7,5 V DC) the power supply comes from the upstream bus coupler

Product Description

Inline controller with a local INTERBUS bus interface for the inline installation system, and programming possible according to IEC 61131-3, complete with accessories (connector and marking surface)
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top