| Parameter | Value |
|---|---|
| GTIN | 4017918185992 |
| Orderkey | 2729800 |
| Catalog page | Page 93 (AX-2005) |
| Depth (Note) | 71.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 109.8 mm |
| Height (Note) | 119.8 mm |
| (Power supply) | 160 Bit (INTERBUS-Slave) |
| Country of origin | DE (Germany) |
| (Data interfaces) | Analog supply (24 V DC) ≤ 0.5 A |
| Shock (Dimensions) | 25g, Criterion 1, according to IEC 60068-2-27 |
| Custom tariff number | 85371091 |
| Weight (Control system) | 320 g |
| Mass storage (Direct I/Os) | 330 kByte |
| Number (Mechanical design) | 1 |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Program memory (Direct I/Os) | typ. 384 kByte (32 K instructions (IL)) |
| Interface (Mechanical design) | Parameterization/operation/diagnostics |
| Engineering tool (Direct I/Os) | PC WORX |
| Input name (Fieldbus function) | Digital inputs |
| Output name (Fieldbus function) | Digital outputs |
| Shock (IEC 61131 runtime system) | 25g, Criterion 1, according to IEC 60068-2-27 |
| Supply voltage (Data interfaces) | 24 V DC |
| Degree of protection (Dimensions) | IP20 |
| Residual ripple (Data interfaces) | ± 5 % |
| Vibration (operation) (Dimensions) | 2g, criterion 1 according to IEC 60068-2-6 |
| Input frequency (Fieldbus function) | 40 kHz |
| Limit frequency (Fieldbus function) | 20 kHz |
| Power dissipation (Data interfaces) | max. 3.25 W |
| Diagnostics display (Control system) | No |
| Number of inputs (Fieldbus function) | 4 |
| Retentive mass storage (Direct I/Os) | 8 kByte (NVRAM) |
| Weight per Piece (excluding packing) | 342.400 g |
| Air pressure (operation) (Dimensions) | 70 kPa ... 108 kPa (up to 3000 m above sea level) |
| Amount of process data (Power supply) | max. 4096 Bit (INTERBUS-Master) |
| Connection method (Fieldbus function) | Spring-cage connection |
| Connection method (Mechanical design) | 6-pos. MINI DIN socket (PS/2) |
| Diagnostics tool (Ambient conditions) | DIAG+ from version 1.14 |
| Engineering tool (Ambient conditions) | PC WORX |
| Number of control tasks (Direct I/Os) | 8 |
| Number of outputs (Fieldbus function) | 2 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Controller redundancy (Control system) | No |
| Supply voltage range (Data interfaces) | 19.2 V DC ... 30 V DC |
| Transmission speed (Mechanical design) | 19200 Baud |
| Number of parameter data (Power supply) | max. 8 Byte (configurable) |
| Connection technology (Fieldbus function) | 2, 3, 4-wire |
| Power supply connection (Data interfaces) | 8-pos. Inline connector |
| Number of supported devices (Power supply) | max. 512 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Description of the input (Fieldbus function) | Interrupt input, fast counter, pulse generator |
| Air pressure (storage/transport) (Dimensions) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 5 % ... 85 % (non-condensing) |
| Typical current consumption (Data interfaces) | 153 mA (no local bus device connected during idling, bus inactive) |
| Utilization restriction (Key Commercial Data) | 1 |
| Vibration (operation) (IEC 61131 runtime system) | 2g, criterion 1 according to IEC 60068-2-6 |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 75 °C |
| Number of pulse direction outputs (Fieldbus function) | 2 |
| Permissible humidity (storage/transport) (Dimensions) | 5 % ... 85 % (non-condensing) |
| Maximum output current per channel (Fieldbus function) | 500 mA |
| Number of devices with parameter channel (Power supply) | max. 62 |
| Vibration (storage/transport) (IEC 61131 runtime system) | 2g, criterion 1 according to IEC 60068-2-6 |
| Number of local bus devices that can be connected (Power supply) | max. 63 (observe current consumption) |
| Number of supported branch terminals with remote bus branch (Power supply) | max. 15 |
| Max. total permissible current consumption of all I/O terminal blocks (Data interfaces) | Communications power (7,5 V DC) ≤ 2 A DC |
Technical specifications and performance data