Service time: Monday to Friday 9:00-18:00
ILC 200 IB - ILC 200 IB 2729800 PHOENIX CONTACT Controller
In Stock Hot Product

ILC 200 IB

ILC 200 IB 2729800 PHOENIX CONTACT Controller

$0.00USD
3026 in stock
Key Specifications
GTIN:4017918185992
Orderkey:2729800
Catalog page:Page 93 (AX-2005)
Depth (Note):71.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918185992
Orderkey2729800
Catalog pagePage 93 (AX-2005)
Depth (Note)71.5 mm
Packing unit1 pc
Width (Note)109.8 mm
Height (Note)119.8 mm
(Power supply)160 Bit (INTERBUS-Slave)
Country of originDE (Germany)
(Data interfaces)Analog supply (24 V DC) ≤ 0.5 A
Shock (Dimensions)25g, Criterion 1, according to IEC 60068-2-27
Custom tariff number85371091
Weight (Control system)320 g
Mass storage (Direct I/Os)330 kByte
Number (Mechanical design)1
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Program memory (Direct I/Os)typ. 384 kByte (32 K instructions (IL))
Interface (Mechanical design)Parameterization/operation/diagnostics
Engineering tool (Direct I/Os)PC WORX
Input name (Fieldbus function)Digital inputs
Output name (Fieldbus function)Digital outputs
Shock (IEC 61131 runtime system)25g, Criterion 1, according to IEC 60068-2-27
Supply voltage (Data interfaces)24 V DC
Degree of protection (Dimensions)IP20
Residual ripple (Data interfaces)± 5 %
Vibration (operation) (Dimensions)2g, criterion 1 according to IEC 60068-2-6
Input frequency (Fieldbus function)40 kHz
Limit frequency (Fieldbus function)20 kHz
Power dissipation (Data interfaces)max. 3.25 W
Diagnostics display (Control system)No
Number of inputs (Fieldbus function)4
Retentive mass storage (Direct I/Os)8 kByte (NVRAM)
Weight per Piece (excluding packing)342.400 g
Air pressure (operation) (Dimensions)70 kPa ... 108 kPa (up to 3000 m above sea level)
Amount of process data (Power supply)max. 4096 Bit (INTERBUS-Master)
Connection method (Fieldbus function)Spring-cage connection
Connection method (Mechanical design)6-pos. MINI DIN socket (PS/2)
Diagnostics tool (Ambient conditions)DIAG+ from version 1.14
Engineering tool (Ambient conditions)PC WORX
Number of control tasks (Direct I/Os)8
Number of outputs (Fieldbus function)2
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Controller redundancy (Control system)No
Supply voltage range (Data interfaces)19.2 V DC ... 30 V DC
Transmission speed (Mechanical design)19200 Baud
Number of parameter data (Power supply)max. 8 Byte (configurable)
Connection technology (Fieldbus function)2, 3, 4-wire
Power supply connection (Data interfaces)8-pos. Inline connector
Number of supported devices (Power supply)max. 512
Ambient temperature (operation) (Dimensions)-25 °C ... 55 °C
Description of the input (Fieldbus function)Interrupt input, fast counter, pulse generator
Air pressure (storage/transport) (Dimensions)66 kPa ... 108 kPa (up to 3500 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 85 % (non-condensing)
Typical current consumption (Data interfaces)153 mA (no local bus device connected during idling, bus inactive)
Utilization restriction (Key Commercial Data)1
Vibration (operation) (IEC 61131 runtime system)2g, criterion 1 according to IEC 60068-2-6
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 75 °C
Number of pulse direction outputs (Fieldbus function)2
Permissible humidity (storage/transport) (Dimensions)5 % ... 85 % (non-condensing)
Maximum output current per channel (Fieldbus function)500 mA
Number of devices with parameter channel (Power supply)max. 62
Vibration (storage/transport) (IEC 61131 runtime system)2g, criterion 1 according to IEC 60068-2-6
Number of local bus devices that can be connected (Power supply)max. 63 (observe current consumption)
Number of supported branch terminals with remote bus branch (Power supply)max. 15
Max. total permissible current consumption of all I/O terminal blocks (Data interfaces)Communications power (7,5 V DC) ≤ 2 A DC

Product Description

Inline controller, without connector and labeling surface. The controller is installed by replacing a standard Inline bus coupler. Like a bus coupler, it links the station to the priority INTERBUS net
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide