| Parameter | Value |
|---|---|
| GTIN | 4046356174107 |
| Orderkey | 2916532 |
| Catalog page | Page 19 (AX-2011) |
| Depth (Note) | 71.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 80 mm |
| Height (Note) | 119.8 mm |
| (Direct I/Os) | PC WORX EXPRESS |
| Country of origin | DE (Germany) |
| Shock (Dimensions) | 25g, Criterion 1, according to IEC 60068-2-27 |
| Custom tariff number | 85371091 |
| (Ambient conditions) | PC WORX EXPRESS |
| Weight (Control system) | 295 g |
| Supply voltage (PROFINET) | 24 V DC |
| Mass storage (Direct I/Os) | 512 kByte |
| Number (Mechanical design) | 2 |
| Residual ripple (PROFINET) | ± 5 % |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Power dissipation (PROFINET) | max. 5 W |
| Program memory (Direct I/Os) | 512 kByte |
| Realtime clock (Direct I/Os) | Yes |
| Interface (Mechanical design) | Ethernet 10Base-T/100Base-TX |
| Engineering tool (Direct I/Os) | PC WORX |
| Input name (Fieldbus function) | Digital inputs |
| Output name (Fieldbus function) | Digital outputs |
| Supply voltage range (PROFINET) | 19.2 V DC ... 30 V DC |
| Shock (IEC 61131 runtime system) | 25g, Criterion 1, according to IEC 60068-2-27 |
| Degree of protection (Dimensions) | IP20 |
| Device function (Data interfaces) | PROFINET device |
| Vibration (operation) (Dimensions) | 5g |
| Max. current consumption (PROFINET) | 870 mA (370 mA communications power + 500 mA analog voltage supply) |
| Diagnostics display (Control system) | No |
| Number of inputs (Fieldbus function) | 8 |
| Retentive mass storage (Direct I/Os) | 48 kByte (NVRAM) |
| Weight per Piece (excluding packing) | 356.100 g |
| Air pressure (operation) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Amount of process data (Power supply) | max. 4096 Bit (INTERBUS) |
| Connection method (Fieldbus function) | Spring-cage connection |
| Connection method (Mechanical design) | RJ45 socket |
| Diagnostics tool (Ambient conditions) | DIAG+ |
| Engineering tool (Ambient conditions) | PC WORX |
| Number of control tasks (Direct I/Os) | 8 |
| Number of outputs (Fieldbus function) | 4 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Controller redundancy (Control system) | No |
| REACh SVHC (Standards and Regulations) | 1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4 |
| Transmission speed (Mechanical design) | 10/100 Mbps |
| Typical current consumption (PROFINET) | 210 mA |
| Configuration tool (Ambient conditions) | Config+ Version 1.01 or later |
| Connection technology (Fieldbus function) | 2, 3, 4-wire |
| Number of supported devices (Power supply) | max. 128 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Vibration (operation) (IEC 61131 runtime system) | 5g |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Permissible humidity (storage/transport) (Dimensions) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Maximum output current per channel (Fieldbus function) | 500 mA |
| Number of devices with parameter channel (Power supply) | max. 24 |
| Vibration (storage/transport) (IEC 61131 runtime system) | 5g |
| Number of local bus devices that can be connected (Power supply) | max. 63 (observe current consumption) |
| Number of supported branch terminals with remote bus branch (Power supply) | max. 3 |