Service time: Monday to Friday 9:00-18:00
ILC 151 GSM/GPRS - ILC 151 GSM/GPRS 2700977 PHOENIX CONTACT Controller
In Stock Hot Product

ILC 151 GSM/GPRS

ILC 151 GSM/GPRS 2700977 PHOENIX CONTACT Controller

$0.00USD
3795 in stock
Key Specifications
GTIN:4046356665537
Orderkey:2700977
Catalog page:Page 83 (C-6-2017)
Depth (Note):71.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356665537
Orderkey2700977
Catalog pagePage 83 (C-6-2017)
Depth (Note)71.5 mm
Packing unit1 pc
Width (Note)85 mm
Height (Note)119.8 mm
(Control system)PC WORX EXPRESS
Country of originDE (Germany)
Shock (Dimensions)25g, Criterion 1, according to IEC 60068-2-27
Custom tariff number85371091
Shock (General data)25g, Criterion 1, according to IEC 60068-2-27
(Ambient conditions)PC WORX EXPRESS
Weight (Power supply)285 g
Number (Fieldbus function)1
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Input name (Data interfaces)Digital inputs
Supply voltage (Direct I/Os)24 V DC
Immunity to EF (General data)Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Interface (Fieldbus function)GSM / GPRS
Mass storage (Control system)512 kByte
Output name (Data interfaces)Digital outputs
Processor (Mechanical design)Altera Nios II 64 MHz
Residual ripple (Direct I/Os)± 5 %
Immunity to ESD (General data)Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Safety function (Power supply)No
Power dissipation (Direct I/Os)max. 5 W
Program memory (Control system)512 kByte
Realtime clock (Control system)Yes
Immunity to burst (General data)Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
Immunity to surge (General data)Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
Degree of protection (Dimensions)IP20
Engineering tool (Control system)PC WORX
Diagnostics display (Power supply)No
Number of inputs (Data interfaces)16
Supply voltage range (Direct I/Os)19.2 V DC ... 30 V DC
Vibration (operation) (Dimensions)5g
Connection method (Data interfaces)Spring-cage connection
Number of outputs (Data interfaces)4
Controller redundancy (Power supply)No
Interference emission (General data)Noise emission test as per EN 61000-6-4 EN 55011 Class A
Vibration (operation) (General data)5g
Weight per Piece (excluding packing)350.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Connection method (Fieldbus function)SIM card, SMA antenna connection
Diagnostics tool (Ambient conditions)DIAG+
Engineering tool (Ambient conditions)PC WORX
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Max. current consumption (Direct I/Os)860 mA (360 mA communications power + 500 mA analog voltage supply)
REACh SVHC (Standards and Regulations)1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
Transmission speed (Fieldbus function)500 kBaud / 2 MBaud (can be switched)
Configuration tool (Ambient conditions)Config+ Version 1.01 or later
Connection technology (Data interfaces)2, 3, 4-wire
Retentive mass storage (Control system)48 kByte (NVRAM)
Number of control tasks (Control system)8
Interface description (Fieldbus function)GSM / GPRS
Typical current consumption (Direct I/Os)210 mA
Description of the input (Data interfaces)EN 61131-2 type 1 NPN/PNP
Ambient temperature (operation) (Dimensions)-25 °C ... 55 °C
Electromagnetic compatibility (General data)Conformance with EMC Directive 2014/30/EU
Vibration (storage/transport) (General data)5g
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)10 % ... 95 % (according to DIN EN 61131-2)
Utilization restriction (Key Commercial Data)1
Amount of process data (IEC 61131 runtime system)max. 4096 Bit (INTERBUS)
Immunity to conducted interference (General data)Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 85 °C
Maximum output current per channel (Data interfaces)500 mA
Programming languages supported (Ambient conditions)Programming in acc. with IEC 61131-3
Permissible humidity (storage/transport) (Dimensions)10 % ... 95 % (according to DIN EN 61131-2)
Number of supported devices (IEC 61131 runtime system)max. 128
Number of devices with parameter channel (IEC 61131 runtime system)max. 16
Number of local bus devices that can be connected (IEC 61131 runtime system)max. 63 (observe current consumption)
Number of supported branch terminals with remote bus branch (IEC 61131 runtime system)max. 3

Product Description

Inline controller with Ethernet interface and GSM modem for coupling to other controls or systems, and possibility of programming according to IEC 61131-3, complete with connector and marking surface.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top