| Parameter | Value |
|---|---|
| GTIN | 4017918907471 |
| Orderkey | 2862246 |
| Catalog page | Page 133 (C-6-2017) |
| Depth (Note) | 71.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 85 mm |
| (Interfaces) | max. 176 Byte (Output) |
| Height (Note) | 119.8 mm |
| Country of origin | DE (Germany) |
| (Inline potentials) | FE / FE D-SUB 500 V |
| Custom tariff number | 85389091 |
| Designation (General) | Inline local bus |
| (Electrical isolation) | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Operation: 25g, 11 ms duration, semi-sinusoidal shock impulse |
| Designation (Interfaces) | System limits of the bus coupler |
| No. of channels (General) | 1 |
| Dimensional drawing (Note) | |
| Connection method (General) | Inline data jumper |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Transmission speed (General) | 500 kbps |
| Number of positions (General) | 9 |
| Net weight (Ambient conditions) | 240 g |
| Test section (Inline potentials) | 500 V |
| Degree of protection (Dimensions) | IP20 |
| Mounting type (Ambient conditions) | DIN rail |
| (System limits of the bus coupler) | max. 1.25 A (with max. number of connected I/O terminal blocks) |
| Amount of process data (Interfaces) | max. 176 Byte (per station) |
| Weight per Piece (excluding packing) | 240.000 g |
| Air pressure (operation) (Dimensions) | 80 kPa ... 106 kPa (up to 3000 m above sea level) |
| Number of parameter data (Interfaces) | max. 168 Byte (DP/V1 mode) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Mechanical tests (Electrical isolation) | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
| Protection class (Electrical isolation) | III, IEC 61140, EN 61140, VDE 0140-1 |
| Number of supported devices (Interfaces) | max. 63 (per station) |
| Number of configuration data (Interfaces) | max. 168 Byte (DP/V1 mode) |
| Ambient temperature (operation) (Dimensions) | 0 °C ... 55 °C |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 85 % (non-condensing) |
| Utilization restriction (Key Commercial Data) | 1 |
| Designation (System limits of the bus coupler) | Segment circuit supply (US) |
| Supply voltage (System limits of the bus coupler) | 24 V DC |
| Note on weight specifications (Ambient conditions) | with connectors |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Power supply unit (System limits of the bus coupler) | max. 8 A DC (sum of UM+ US) |
| Number of devices with parameter channel (Interfaces) | max. 16 |
| Permissible humidity (storage/transport) (Dimensions) | 85 % (non-condensing) |
| Current consumption (System limits of the bus coupler) | typ. 100 mA (without connected Inline I/O terminals) |
| Supply voltage range (System limits of the bus coupler) | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Number of local bus devices that can be connected (Interfaces) | max. 63 |
| Number of supported branch terminals with remote bus branch (Interfaces) | 0 |