Service time: Monday to Friday 9:00-18:00
IL PB BK DI8 DO4/EF-XC-PAC - IL PB BK DI8 DO4/EF-XC-PAC 2702132 PHOENIX CONTACT Bus coupler
In Stock Hot Product

IL PB BK DI8 DO4/EF-XC-PAC

IL PB BK DI8 DO4/EF-XC-PAC 2702132 PHOENIX CONTACT Bus coupler

$0.00USD
4911 in stock
Key Specifications
GTIN:4046356981774
Orderkey:2702132
(General):max. 244 Byte (Output)
Catalog page:Page 133 (C-6-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356981774
Orderkey2702132
(General)max. 244 Byte (Output)
Catalog pagePage 133 (C-6-2017)
Depth (Note)71.5 mm
Packing unit1 pc
Width (Note)80 mm
(Dimensions)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Height (Note)119.8 mm
Country of originDE (Germany)
(Connection data)Failure of the actuator supply Yes
(Digital outputs)Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Operation: 25g, 11 ms duration, semi-sinusoidal shock impulse
Custom tariff number85176200
Designation (General)System limits of the bus coupler
Note on dimensions (Note)Specfications with connectors
Dimensional drawing (Note)
(Standards and Regulations)No hazardous substances above threshold values
Net weight (Connection data)339.9 g
Output name (Digital inputs)Digital outputs
Input name (Inline potentials)Digital inputs
Mounting type (Connection data)DIN rail
Output voltage (Digital inputs)24 V DC -1 V (At nominal current)
Response time of I/Os (General)typ. 4 ms (aligned I/Os; transmission speed: PROFIBUS 1.5 Mbps, local bus 500 kbps)
Amount of process data (General)max. 488 Byte (per station)
Designation (Ambient conditions)Inline connector
Degree of protection (Dimensions)IP20
Input voltage (Inline potentials)24 V DC
Connection method (Digital inputs)Inline connector
Mechanical tests (Digital outputs)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Number of outputs (Digital inputs)4
Number of parameter data (General)max. 244 Byte (including 14 bytes for the bus coupler, DP/V1, and the local inputs and outputs)
Protection class (Digital outputs)III, IEC 61140, EN 61140, VDE 0140-1
(System limits of the bus coupler)max. 0.98 A
Nominal load, lamp (Digital inputs)12 W
Type of protection (Digital inputs)Short-circuit and overload protection
Nominal load, ohmic (Digital inputs)12 W
Number of inputs (Inline potentials)8
Weight per Piece (excluding packing)339.900 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Connection method (Inline potentials)Inline connector
Number of supported devices (General)max. 63 (per station)
Stripping length (Ambient conditions)8 mm
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Ambient conditions)Spring-cage connection
Connection technology (Digital inputs)3-wire
Diagnostics messages (Connection data)Short-circuit / overload of the digital outputs Yes
Number of configuration data (General)max. 244 Byte (including 5 bytes for the local inputs and outputs)
Type of protection (Inline potentials)Reverse polarity protection
Nominal output voltage (Digital inputs)24 V DC
Nominal load, inductive (Digital inputs)12 VA (1.2 H, 48 Ω)
Connection technology (Inline potentials)3-wire
Typical response time (Inline potentials)approx. 500 µs
Ambient temperature (operation) (Dimensions)-25 °C ... 55 °C
Description of the input (Inline potentials)EN 61131-2 type 1
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)10 % ... 95 % (non-condensing)
Utilization restriction (Key Commercial Data)1
Designation (System limits of the bus coupler)Segment circuit supply (US)
Note on weight specifications (Connection data)with connectors
Nominal input current at UIN (Inline potentials)typ. 3 mA
Supply voltage (System limits of the bus coupler)24 V DC (via Inline connector)
Connection in acc. with standard (Digital outputs)CUL
Input voltage range "0" signal (Inline potentials)-30 V DC ... 5 V DC
Input voltage range "1" signal (Inline potentials)15 V DC ... 30 V DC
Maximum output current per module (Digital inputs)2 A
Number of devices with parameter channel (General)max. 16
Maximum output current per channel (Digital inputs)500 mA
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Power consumption (System limits of the bus coupler)typ. 1.7 W (entire device)
Power supply unit (System limits of the bus coupler)max. 8 A DC (sum of UM+ US)
Conductor cross section AWG max. (Ambient conditions)16
Conductor cross section AWG min. (Ambient conditions)28
Permissible humidity (storage/transport) (Dimensions)10 % ... 95 % (according to DIN EN 61131-2)
Typical input current per channel (Inline potentials)typ. 3 mA
Current consumption (System limits of the bus coupler)6 mA (Without connected peripherals)
Delay at signal change from 0 to 1 (Inline potentials)2.9 ms
Delay at signal change from 1 to 0 (Inline potentials)2.9 ms
Conductor cross section solid max. (Ambient conditions)1.5 mm²
Conductor cross section solid min. (Ambient conditions)0.08 mm²
Supply voltage range (System limits of the bus coupler)19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Conductor cross section flexible max. (Ambient conditions)1.5 mm²
Conductor cross section flexible min. (Ambient conditions)0.08 mm²
Number of local bus devices that can be connected (General)max. 61 (on board I/Os are two devices)
Maximum output current per module / terminal block (Digital inputs)2 A
Number of supported branch terminals with remote bus branch (General)0

Product Description

Inline XC, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, Digital inputs: 8, 24 V DC, connection technology: 3 conductors, Digital outputs: 4, 24 V DC, 500 mA, connection technology: 3 conductors
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top