Service time: Monday to Friday 9:00-18:00
IBS RL 480 MLR R DIO6/1-LK2MBD - IBS RL 480 MLR R DIO6/1-LK2MBD 2734497 PHOENIX CONTACT Motor starter
In Stock Hot Product

IBS RL 480 MLR R DIO6/1-LK2MBD

IBS RL 480 MLR R DIO6/1-LK2MBD 2734497 PHOENIX CONTACT Motor starter

$0.00USD
4276 in stock
Key Specifications
GTIN:4017918974190
Note:Made to Order (non-returnable)
Orderkey:2734497
Catalog page:Page 331 (C-8-2013)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918974190
NoteMade to Order (non-returnable)
Orderkey2734497
Catalog pagePage 331 (C-8-2013)
Depth (Note)138 mm
Packing unit1 pc
Width (Note)185.1 mm
Height (Note)193 mm
Country of originDE (Germany)
(Digital outputs)Module error during self test Message to the master
Ripple (Interfaces)3.6 Vpp
Custom tariff number85389091
Number (Mains connection)1
Protection class (General)I, IEC 61140, EN 61140, VDE 0140-1
Supply voltage (Interfaces)24 V DC
(Standards and Regulations)No hazardous substances above threshold values
Net weight (Digital outputs)3800 g
Mounting type (Digital outputs)on mounting plate
Output current (Digital inputs)0.5 A
Designation (Ambient conditions)INTERBUS
Degree of protection (Dimensions)IP65/IP67
Input name (Motor starter, brake)Digital inputs
Supply voltage range (Interfaces)18.5 V DC ... 32 V DC (including ripple)
Switching rate (Mains connection)5 cycles per minute, maximum
Connection method (Digital inputs)M12 connector
Filter time (Motor starter, brake)3 ms
Frequency range (Mains connection)50 Hz ... 60 kHz
Number of outputs (Digital inputs)1
Type of contact (Motor monitoring)Mechanical relay contact
Type of protection (Digital inputs)Electronic short-circuit/overload protection
Connection method (Mains connection)POWER-COMBICON
Input voltage (Motor starter, brake)24 V DC (DIN EN 61131-2)
Number of positions (Digital inputs)5
Operating voltage (Mains connection)230 V AC ... 480 V AC
Weight per Piece (excluding packing)3,800.000 g
Air pressure (operation) (Dimensions)860 hPa ... 1080 hPa (up to 1500 m above sea level)
Connection voltage (Motor monitoring)12 V AC/DC ... 480 V AC/DC
Motor startup time (Mains connection)1 s
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Ambient conditions)Fiber optics
Diagnostics messages (Digital outputs)Mains failure, phase failure, blown fuse Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Number of positions (Mains connection)8
Pg screw connection (Mains connection)Pg16
Number of inputs (Motor starter, brake)6
Transmission speed (Ambient conditions)2 Mbps
Utilization category (Mains connection)On the basis of AC 3
Connection method (Motor starter, brake)M12 connector
Connection technology (Motor monitoring)POWER-COMBICON terminal strips
Nominal current range (Mains connection)0.2 A ... 8 A (parameterizable, observe derating)
Parameterization (Motor starter, output)Via INTERBUS
Continuous load current (Motor monitoring)max. 1 A
Number of positions (Motor starter, brake)5
Overspeed tripping (Motor starter, output)≥ 40 A (after 1 second at Inom> 3.6 A)
Ambient temperature (operation) (Dimensions)0 °C ... 55 °C
Connection technology (Motor starter, brake)3, 4-wire
Air pressure (storage/transport) (Dimensions)660 hPa ... 1080 hPa (up to 3500 m above sea level)
Permissible humidity (operation) (Dimensions)100 %
Utilization restriction (Key Commercial Data)1
Air clearances and creepage distances (General)according to EN 50178: 1998
Designation connection point (Mains connection)X10
Power supply for sensors (Motor starter, brake)UINI= US1minus 1 V 50 mA Protected against inductive reverse voltages, electronically protected against short-circuiting
Designation (Power supply for module electronics)Mains connection
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 70 °C
Input voltage range "0" signal (Motor starter, brake)0 V ... 5 V
Input voltage range "1" signal (Motor starter, brake)11 V ... 30 V
Permissible humidity (storage/transport) (Dimensions)95 % (non-condensing)
Connection method (Power supply for module electronics)POWER-COMBICON with silver contacts
Operating voltage (Power supply for module electronics)230 V AC ... 480 V AC ±10 % (conductor voltage)
Typical input current per channel (Motor starter, brake)5 mA (for US1= 24 V)
Number of positions (Power supply for module electronics)4
Minimum output voltage with nominal current (Digital inputs)US1minus 2 V
Designation connection point (Power supply for module electronics)Terminal strip X11 and X12
Max. current carrying capacity (Power supply for module electronics)20 A
Permissible conductor cross section (Power supply for module electronics)2.5 mm² ... 4 mm²

Product Description

Electromechanical inverter starter controller for INTERBUS; Fibre optic technology with 2 Mbaud, inputs (24 V DC), integrated motor guard relay (220 V AC to 480 V AC, max. 8 A), sensor connection via
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top