| Parameter | Value |
|---|---|
| GTIN | 4017918132552 |
| Note | Made to Order (non-returnable) |
| (Cable) | No hazardous substances above threshold values |
| Orderkey | 2723123 |
| Catalog page | Page 428 (C-2-2017) |
| Packing unit | 1 M |
| (General data) | -30 °C ... 70 °C (cable, flexible installation) |
| Country of origin | DE (Germany) |
| China RoHS (Cable) | Environmentally friendly use period: unlimited = EFUP-e |
| Custom tariff number | 85444993 |
| Shielding (General data) | Braided copper wires |
| Cable type (General data) | INTERBUS |
| Attenuation (General data) | ≤ 15 dB/km (at 256 kHz) |
| Wire colors (General data) | Green-yellow, white-brown, gray-pink |
| Acceleration (General data) | 3.2 m/s² |
| Cable weight (General data) | 70 kg/km |
| Signal speed (General data) | 0.66 c |
| Overall twist (General data) | 3 pairs to the core |
| Twisted pairs (General data) | 2 cores to the pair |
| Bending radius (General data) | 120 mm |
| Cable capacity (General data) | ≤ 60 nF/km (At 800 Hz) |
| Wave impedance (General data) | 120 Ω ±20 % (at 64 kHz) |
| AWG signal line (General data) | 24 |
| Cable structure (General data) | 3 x 2 x 0.22 mm² |
| Loop resistance (General data) | ≤ 159.80 Ω/km |
| Traversing path (General data) | 10 m |
| Traversing rate (General data) | 1.6 m/s |
| Flame resistance (General data) | according to VDE 0472, Part 4, test type B |
| Conductor material (General data) | Bare Cu litz wires |
| Coupling resistance (General data) | < 250.00 mΩ/m (at 30 MHz) |
| Signal type/category (General data) | INTERBUS |
| Insulation resistance (General data) | ≥ 5 GΩ*km |
| Weight per Piece (excluding packing) | 70.680 g |
| External sheath, color (General data) | may green RAL 6017 |
| Nominal voltage, cable (General data) | 250 V (Peak value, not for high-power applications) |
| Outer sheath, material (General data) | PUR |
| Test voltage Core/Core (General data) | 1500 Vrms |
| Conductor cross section (General data) | 3x 2x 0.22 mm² |
| Number of bending cycles (General data) | 5000000 |
| Test voltage Core/Shield (General data) | 1000 Vrms |
| Cable type (abbreviation) (General data) | 900 |
| External cable diameter D (General data) | 8 mm |
| Number of positions (Key Commercial Data) | 6 |
| Material conductor insulation (General data) | PE |
| Ambient temperature (operation) (General data) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (General data) | 32x 0.10 mm |
| Near end crosstalk attenuation (NEXT) (General data) | ≥ 61 dB (at 772 kHz) |
| Minimum bending radius, fixed installation (General data) | 7.5 x D |
| Alternative short product description (Key Commercial Data) | Remote bus cable |
| Minimum bending radius, flexible installation (General data) | 15 x D |
Technical specifications and performance data