| Parameter | Value |
|---|---|
| 2732994 IBS PCI SC SYSKIT E | |
| I/O | 16 bytes I/O, PnP |
| Type | PC card |
| Depth | 20 mm |
| Width | 168 mm |
| Driver | Windows NT |
| Format | Short plug-in card, 1-slot |
| Height | 107 mm |
| Input name | Digital inputs |
| Interrupts | 1 IRQ, PnP |
| Designation | SC, HF, PF, BSA, FAIL |
| Output name | Digital outputs |
| Product type | PC controller board |
| Mounting type | In the host system |
| Set comprises | 2732981 IBS PCI SC SYSKIT |
| Control system | IBM-compatible PCs with PCI slot |
| Output voltage | 24 V DC |
| Supply voltage | 5 V DC |
| Diagnostics tool | DIAG+ from version 1.0x |
| Number of inputs | 6 (EN 61131-2 type 1) |
| Operating system | Windows NT |
| Connection method | 9-pos. D-SUB female connector, with electrical isolation |
| Local diagnostics | SC, HF, PF, BSA, FAIL INTERBUS Status display via LED |
| Number of outputs | 2 |
| Configuration tool | CMD from version 4.5x |
| Monitored function | INTERBUS |
| Notes on operation | From item revision 15, the controller board will no longer be equipped with a NVRAM (Non-Volatile Random-Access-Memory) due to component discontinuation.The fundamental functionality of the controller board is not affected. In applications that access the NVRAM, applicative countermeasures will have to be taken. |
| Transmission speed | 500 kbps |
| Note on application | Only for industrial use |
| Transmission medium | Copper |
| Degree of protection | IP20 (Must be installed in a device with IP20) |
| Supply voltage range | ± 5 % (including ripple) |
| Application interface | HFI |
| Connection technology | FLK cable connector (14-pos.) |
| Optical representation | Status display via LED |
| Width / Height / Depth | 168 mm / 107 mm / 20 mm |
| Power supply connection | Via PCI bus |
| Air pressure (operation) | 860 hPa ... 1080 hPa (up to 2000 m above sea level) |
| Nominal input voltage UIN | 24 V DC |
| Typical current consumption | 0.7 A |
| Ambient temperature (operation) | 0 °C ... 55 °C (acc. to EN 60204-1) |
| Air pressure (storage/transport) | 660 hPa ... 1080 hPa (up to 3000 m above sea level) |
| Permissible humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum output current per channel | 0.5 A |
| Ambient temperature (storage/transport) | -25 °C ... 75 °C (acc. to EN 60204-1) |
| Number of devices with parameter channel | max. 126 |
| Maximum power dissipation for nominal condition | max. 3.5 W |
Technical specifications and performance data
Installation and operation guide