| Parameter | Value |
|---|---|
| GTIN | 4017918141288 |
| Note | Made to Order (non-returnable) |
| (Cable) | No hazardous substances above threshold values |
| Orderkey | 2723152 |
| Packing unit | 1 M |
| (General data) | -5 °C ... 70 °C (cable, flexible installation) |
| Country of origin | DE (Germany) |
| China RoHS (Cable) | Environmentally friendly use period: unlimited = EFUP-e |
| Custom tariff number | 85444993 |
| Shielding (General data) | Tinned copper braided shield |
| Attenuation (General data) | ≤ 10 dB/km (at 256 kHz) |
| Wire colors (General data) | green-yellow, white-brown, gray-pink, red, blue, green/yellow |
| Signal speed (General data) | 0.66 c |
| Overall twist (General data) | 3 pairs and 3 wires to form the core |
| Twisted pairs (General data) | 2 cores to the pair |
| Cable capacity (General data) | ≤ 60 nF/km (At 800 Hz) |
| Wave impedance (General data) | 110 Ω ±20 Ω (at 64 kHz) |
| Cable structure (General data) | 3 x 2 x 0.22 mm² + 3 x 1 mm² |
| Loop resistance (General data) | ≤ 186.00 Ω/km (Data) |
| Flame resistance (General data) | according to VDE 0472, Part 804, test type B |
| Conductor material (General data) | Bare Cu litz wires |
| Coupling resistance (General data) | < 250.00 mΩ/m (at 30 MHz) |
| Signal type/category (General data) | INTERBUS |
| Insulation resistance (General data) | ≥ 5 GΩ*km (Data) |
| Weight per Piece (excluding packing) | 137.600 g |
| External sheath, color (General data) | black RAL 9005 |
| Inner sheath thickness (General data) | 0.9 mm |
| Material, inner sheath (General data) | PVC |
| Nominal voltage, cable (General data) | 250 V (Peak value, not for high-power applications) |
| Outer sheath, material (General data) | PVC |
| Test voltage Core/Core (General data) | 1500 Vrms |
| Conductor cross section (General data) | 3x 2x 0.22 mm² (Data) |
| Test voltage Core/Shield (General data) | 1000 Vrms |
| External cable diameter D (General data) | 9.7 mm ±0,3 mm |
| Number of positions (Key Commercial Data) | 9 |
| Material conductor insulation (General data) | PE |
| Ambient temperature (operation) (General data) | -30 °C ... 70 °C (cable, fixed installation) |
| Conductor structure signal line (General data) | 7x 0.20 mm |
| Core diameter including insulation (General data) | 1 mm (Data) |
| Conductor structure, voltage supply (General data) | 14x 0.30 mm |
| Near end crosstalk attenuation (NEXT) (General data) | ≥ 61 dB (at 772 kHz) |
| Minimum bending radius, fixed installation (General data) | 7.5 x D |
| Alternative short product description (Key Commercial Data) | Installation remote bus cable |
| Minimum bending radius, flexible installation (General data) | 15 x D |
Technical specifications and performance data
Installation and operation guide