Key Specifications
Type:modular
Depth:71.5 mm
Width:12.2 mm
Height:135 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Typemodular
Depth71.5 mm
Width12.2 mm
Height135 mm
Current drawtyp. 29 mA
Product typeI/O component
ID code (hex)04
Mounting typeDIN rail mounting
ID code (dec.)04
Product familyInline
Supply voltage24 V DC (via voltage jumper)
Connection nameInline connector
Register length0 bit
Article revision07
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)
Stripping length8 mm
Connection methodInline data jumper
Length code (dec)0
Length code (hex)0
Scope of deliveryincluding Inline connector and labeling field
Input address area0 Byte
Special propertieswith remote bus branch
Transmission speed2 Mbps
Dimensional drawing
Note on applicationOnly for industrial use
Output address area0 Byte
Degree of protectionIP20
Process data channel0 bit
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Transmission physicsRS-485
Required parameter data0 Byte
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section AWG28 ... 16
Required configuration data0 Byte
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Ambient temperature (operation)-25 °C ... 55 °C
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Maximum power dissipation for nominal condition0.7 W
Number of local bus devices that can be connectedmax. 63 (Consider the logic current consumed by the devices; the branch terminal does not count as an Inline station device.)
Test voltage: 5 V supply incoming remote bus / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply outgoing remote bus, electrically isolated from functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from the functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 5 V supply, outgoing remote bus500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 5 V supply, incoming remote bus500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, incoming remote bus500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, outgoing remote bus500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 24 V main supply, 24 V segment supply500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 24 V main supply, 24 V segment supply500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply incoming remote bus500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply outgoing remote bus500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V communications power, 24 V analog supply, 24 V bus terminal module supply, 5 V communications power, bus branch terminal electrically isolated from functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 24 V main supply, 24 V segment supply500 V AC, 50 Hz, 1 min.

Product Description

INTERBUS branch terminal block, 2MBD, with accessories, with remote bus switch, 24 V DC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty