| Parameter | Value |
|---|---|
| GTIN | 4017918894443 |
| Orderkey | 2861593 |
| Catalog page | Page 131 (C-6-2017) |
| Depth (Note) | 71.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 85 mm |
| Height (Note) | 119.8 mm |
| Country of origin | DE (Germany) |
| Custom tariff number | 85389091 |
| Designation (General) | Inline local bus |
| No. of channels (General) | 2 |
| Dimensional drawing (Note) | |
| Connection method (General) | Inline data jumper |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Transmission speed (General) | 500 kbps |
| Transmission physics (General) | Copper |
| Net weight (Ambient conditions) | 210 g |
| Degree of protection (Dimensions) | IP20 |
| Mounting type (Ambient conditions) | DIN rail |
| (System limits of the bus coupler) | max. 1.25 A (with max. number of connected I/O terminal blocks) |
| Weight per Piece (excluding packing) | 210.000 g |
| Air pressure (operation) (Dimensions) | 80 kPa ... 106 kPa (up to 3000 m above sea level) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 75 % ... 85 % (in the range of -25°C ... +55°C, appropriate measures against increased humidity (> 85%) must be taken.) |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Designation (System limits of the bus coupler) | Supply of analog modules (UANA) |
| Supply voltage (System limits of the bus coupler) | 24 V DC |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Connection in acc. with standard (Inline potentials) | CUL |
| Power supply unit (System limits of the bus coupler) | max. 0.5 A DC (observe derating) |
| Number of devices with parameter channel (Interfaces) | 62 |
| Permissible humidity (storage/transport) (Dimensions) | 75 % ... 85 % (Slight temporary condensation may sometimes appear on the housing, e.g. when the terminal block is brought out of a vehicle into an enclosed room.) |
| Current consumption (System limits of the bus coupler) | typ. 100 mA (without connected Inline I/O terminals) |
| Supply voltage range (System limits of the bus coupler) | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Number of local bus devices that can be connected (Interfaces) | max. 63 |
| Number of supported branch terminals with remote bus branch (Interfaces) | max. 15 |
Technical specifications and performance data
Installation and operation guide