| Parameter | Value |
|---|---|
| GTIN | 4017918942007 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2863669 |
| Catalog page | Page 245 (AX-2009) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| (Digital outputs) | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Operation: 25g, 11 ms duration, semi-sinusoidal shock impulse |
| Custom tariff number | 85389091 |
| Designation (General) | Inline local bus |
| No. of channels (General) | 2 |
| Connection method (General) | Inline data jumper |
| Depth (Key Commercial Data) | 71.5 mm |
| Width (Key Commercial Data) | 146.4 mm |
| Height (Key Commercial Data) | 140.5 mm |
| Output name (Digital inputs) | Digital outputs |
| Transmission speed (General) | 500 kbps |
| Number of positions (General) | 6 |
| Input name (Inline potentials) | Digital inputs |
| Transmission physics (General) | Copper |
| Net weight (Ambient conditions) | 700.3 g |
| Output voltage (Digital inputs) | 24 V DC |
| Degree of protection (Dimensions) | IP20 |
| Input voltage (Inline potentials) | 24 V DC |
| Connection method (Digital inputs) | Spring-cage connection |
| Mechanical tests (Digital outputs) | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
| Mounting type (Ambient conditions) | DIN rail |
| Number of outputs (Digital inputs) | 16 |
| (System limits of the bus coupler) | max. 1.25 A (with max. number of connected I/O terminal blocks (24 V DC supply)) |
| Number of inputs (Inline potentials) | max. 16 |
| Weight per Piece (excluding packing) | 700.300 g |
| Air pressure (operation) (Dimensions) | 80 kPa ... 106 kPa (up to 3000 m above sea level) |
| Connection method (Inline potentials) | Spring-cage connection |
| Connection technology (Digital inputs) | 2, 3-wire |
| Dimensional drawing (Key Commercial Data) | |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Description of the input (Inline potentials) | EN 61131-2 type 1 |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 95 % (non-condensing) |
| Designation (System limits of the bus coupler) | Segment circuit supply (US) |
| Supply voltage (System limits of the bus coupler) | 24 V DC |
| Power supply unit (System limits of the bus coupler) | max. 8 A DC (sum of UM+ US) |
| Permissible humidity (storage/transport) (Dimensions) | 95 % (non-condensing) |
| Current consumption (System limits of the bus coupler) | typ. 100 mA (without connected Inline I/O terminals) |
| Supply voltage range (System limits of the bus coupler) | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Number of local bus devices that can be connected (Interfaces) | 63 (observe total permissible current consumption) |
| Number of supported branch terminals with remote bus branch (Interfaces) | max. 15 |
Technical specifications and performance data
Installation and operation guide