| Parameter | Value |
|---|---|
| GTIN | 4017918062736 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2752767 |
| (General) | No hazardous substances above threshold values |
| Catalog page | Page 251 (C-8-2013) |
| Packing unit | 1 pc |
| Width (Note) | 118 mm |
| (Interfaces) | 85 mA (to US) |
| Height (Note) | 117 mm |
| Length (Note) | 116 mm |
| (Power supply) | I/O voltage/Ground conductor 500 V AC 50 Hz 1 min. |
| Weight (Inputs) | 540 g |
| China RoHS (General) | Environmentally friendly use period: unlimited = EFUP-e |
| Custom tariff number | 85389091 |
| Designation (Inputs) | Termination block |
| Mounting type (Inputs) | DIN rail |
| I/O voltage (Interfaces) | 24 V DC |
| Connection method (Inputs) | Screw connection |
| Test section (Power supply) | Bus/Inputs 500 V AC 50 Hz 1 min. |
| Interface (Ambient conditions) | ST local bus |
| Degree of protection (Dimensions) | IP20 |
| Quantization (Electrical isolation) | 0.1 K (for Celsius scale, 0.056 K for Fahrenheit scale) |
| Communications power UL (Interfaces) | 9 V DC (from the ST local bus) |
| Weight per Piece (excluding packing) | 540.000 g |
| Max. current consumption (Interfaces) | 100 mA (from the ST local bus) |
| Connection method (Ambient conditions) | ST local bus connector |
| Number of inputs (Electrical isolation) | 4 |
| Transmission speed (Ambient conditions) | 500 kbps |
| Typical current consumption (Interfaces) | 85 mA (from the ST local bus) |
| Conductor cross section AWG max. (Inputs) | 12 |
| Conductor cross section AWG min. (Inputs) | 24 |
| Measuring principle (Electrical isolation) | Sigma/Delta process |
| Process data update (Electrical isolation) | 258 ms (per channel/816 ms all channels (for 50 Hz suppression)) |
| Conductor cross section solid max. (Inputs) | 2.5 mm² |
| Conductor cross section solid min. (Inputs) | 0.2 mm² |
| Connection technology (Electrical isolation) | 2, 3, 4-wire |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Conductor cross section flexible max. (Inputs) | 2.5 mm² |
| Conductor cross section flexible min. (Inputs) | 0.2 mm² |
| Measured value resolution (Electrical isolation) | 16 bits |
| Measured value representation (Electrical isolation) | 16 bit two's complement |
| Sensor types (RTD) that can be used (Electrical isolation) | PT: -200 °C ... +850 °C, Ni: -60 °C ... +250 °C |
| Basic error limit of the range of values (Electrical isolation) | 0.003 % |
Technical specifications and performance data
Installation and operation guide