Key Specifications
GTIN:4017918105020
Note:Made to Order (non-returnable)
Orderkey:2750565
Catalog page:Page 250 (C-8-2013)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918105020
NoteMade to Order (non-returnable)
Orderkey2750565
Catalog pagePage 250 (C-8-2013)
Packing unit1 pc
Width (Note)118 mm
(Interfaces)120 mA (from the ST local bus)
Height (Note)117 mm
Length (Note)116 mm
(Power supply)I/O voltage/Ground conductor 500 V AC 50 Hz 1 min.
Weight (Inputs)600 g
Custom tariff number85389091
Interface (Dimensions)ST local bus
Mounting type (Inputs)DIN rail
I/O voltage (Interfaces)± 24 V DC 5 % (ripple)
Test section (Power supply)Bus/Inputs 500 V AC 50 Hz 1 min.
(Standards and Regulations)No hazardous substances above threshold values
Connection method (Dimensions)ST local bus connector
I/O voltage range (Interfaces)20 V DC ... 30 V DC
Transmission speed (Dimensions)500 kbps
Transmission physics (Dimensions)Copper
Communications power UL (Interfaces)9 V DC (from the ST local bus)
Weight per Piece (excluding packing)600.000 g
Max. current consumption (Interfaces)125 mA (without passive sensors)
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
No. of channels (Electrical isolation)4
Basic error limit (Electrical isolation)0.06 %
Typical current consumption (Interfaces)65 mA (without passive sensors)
A/D conversion time (Electrical isolation)10 µs (per channel)
Connection in acc. with standard (General)CUL
Measuring principle (Electrical isolation)Successive approximation
Process data update (Electrical isolation)0.75 ms (per channel/3 ms all channels)
Current input signal (Electrical isolation)4 mA ... 20 mA
Voltage input signal (Electrical isolation)0 V ... 10 V
Connection technology (Electrical isolation)2, 3, 4-wire
Limit frequency (3 dB) (Electrical isolation)29.9 Hz
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Wire break diagnostics (Electrical isolation)Yes, diagnostic bit
Measured value resolution (Electrical isolation)12 bits
Current input quantization (Electrical isolation)3.91 µA
Voltage input quantization (Electrical isolation)2.44 mV
Measured value representation (Electrical isolation)16 bit two's complement
Note on the number of channels (Electrical isolation)differential inputs, voltage or current
Max. power consumption from the local bus (Interfaces)150 mA (from the ST local bus)
Input resistance of voltage input (Electrical isolation)>
Measured value monitoring to the PLC (Electrical isolation)All channels simultaneously