Service time: Monday to Friday 9:00-18:00
IB IL TEMP 2 RTD-PAC - IB IL TEMP 2 RTD-PAC 2861328 PHOENIX CONTACT Inline function terminal
In Stock Hot Product

IB IL TEMP 2 RTD-PAC

IB IL TEMP 2 RTD-PAC 2861328 PHOENIX CONTACT Inline function terminal

$0.00USD
3739 in stock
Key Specifications
GTIN:4017918894269
Orderkey:2861328
Catalog page:Page 165 (C-6-2017)
Depth (Note):71.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918894269
Orderkey2861328
Catalog pagePage 165 (C-6-2017)
Depth (Note)71.5 mm
Packing unit1 pc
Width (Note)12.2 mm
(Dimensions)80 kPa ... 106 kPa (up to 3000 m above sea level, in ATEX Zone 2)
(Interfaces)max. 18 mA
Height (Note)136.8 mm
(Analog inputs)24 V analog supply (analog I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Country of originDE (Germany)
(Inline potentials)0 Ω ... 4 kΩ
Custom tariff number85389091
(Ambient conditions)User error Error message in the process data
Designation (General)Inline local bus
Designation (Interfaces)Supply of analog modules (UANA)
No. of channels (General)2
Dimensional drawing (Note)
Connection method (General)Inline data jumper
Supply voltage (Interfaces)24 V DC (via voltage jumper)
(Standards and Regulations)No hazardous substances above threshold values
Test section (Analog inputs)7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC 50 Hz 1 min.
Transmission speed (General)500 kbps
Input name (Inline potentials)Analog RTD inputs
Power consumption (Interfaces)typ. 587 mW
Net weight (Ambient conditions)67 g
Current consumption (Interfaces)typ. 11 mA
Degree of protection (Dimensions)IP20
Supply voltage range (Interfaces)19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Mounting type (Ambient conditions)DIN rail
Resolution A/D (Inline potentials)16 bit
Operating mode (Ambient conditions)Process data operation with 2 words
Number of inputs (Inline potentials)2
Weight per Piece (excluding packing)67.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Connection method (Inline potentials)Spring-cage connection
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
A/D conversion time (Inline potentials)typ. 120 µs (per channel)
Measuring principle (Inline potentials)Successive approximation
Process data update (Inline potentials)32 ms (both channels with 3-wire technology)
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Connection technology (Inline potentials)2, 3, 4-wire
Diagnostics messages (Ambient conditions)Failure of the internal I/O supply I/O error message sent to the bus coupler
Ambient temperature (operation) (Dimensions)-25 °C ... 55 °C
Description of the input (Inline potentials)Input for resistive temperature sensors
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)10 % ... 95 % (non-condensing)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Measured value representation (Inline potentials)16 bit two's complement
Note on weight specifications (Ambient conditions)with connector
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 85 °C
Linear resistance measuring range (Inline potentials)0 Ω ... 400 Ω
Permissible humidity (storage/transport) (Dimensions)10 % ... 95 % (non-condensing)
Connection in acc. with standard (Electrical isolation)CUL
Sensor types (RTD) that can be used (Inline potentials)Pt, Ni, KTY, Cu sensors, linear resistors
Note regarding the connection technology (Inline potentials)shielded

Product Description

Inline, Temperature recording module, Analogue RTD inputs: 2, connection technology: 2, 3, 4 conductors, transmission speed on local bus: 500 kBit/s, protection rating: IP20, including Inline connecto
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top