| Parameter | Value |
|---|---|
| GTIN | 4017918996406 |
| Orderkey | 2878638 |
| Catalog page | Page 162 (C-6-2017) |
| Depth (Note) | 71.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 48.8 mm |
| (Interfaces) | typ. 32 mA (with maximum load of 58.3 Ω when UV= 5 V) |
| Height (Note) | 136 mm |
| (Analog inputs) | typ. 85 mA (with UV= 5 V) |
| (Analog outputs) | Logic/functional earth ground (isolating distance) 500 V AC 50 Hz 1 min. |
| Country of origin | DE (Germany) |
| (Inline potentials) | ±1 mV/V, ±2 mV/V, ±3 mV/V, ±4 mV/V |
| Custom tariff number | 85389091 |
| (Ambient conditions) | Peripheral fault Error message in the process data |
| Designation (General) | Inline local bus |
| Designation (Interfaces) | Supply of analog modules (UANA) |
| Impedance (Analog inputs) | > 58.3 Ω (typical; permissible total resistance of the strain gauge) |
| No. of channels (General) | 2 |
| Dimensional drawing (Note) | |
| Connection method (General) | Inline data jumper |
| Supply voltage (Interfaces) | 24 V DC (via voltage jumper) |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Transmission speed (General) | 500 kbps |
| Test section (Analog outputs) | Logic/analog I/O (digital isolator) 500 V AC 50 Hz 1 min. |
| Output current (Analog inputs) | typ. 55 mA (with UV= 3.3 V) |
| Output voltage (Analog inputs) | 5 V |
| Power consumption (Interfaces) | typ. 0.76 W (Device in nominal operation) |
| Transmission physics (General) | Copper |
| Net weight (Ambient conditions) | 190 g |
| Current consumption (Interfaces) | typ. 8 mA (without strain gauge) |
| Degree of protection (Dimensions) | IP20 |
| Number of outputs (Analog inputs) | 2 |
| Supply voltage range (Interfaces) | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Mounting type (Ambient conditions) | DIN rail |
| Output description (Analog inputs) | Voltage output |
| Characteristics (Inline potentials) | +1 mV/V, +2 mV/V, +3 mV/V, +4 mV/V |
| Operating mode (Ambient conditions) | Process data operation with 3 words, PCP with 1 word |
| Number of inputs (Inline potentials) | 2 |
| Weight per Piece (excluding packing) | 190.000 g |
| Air pressure (operation) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Bridge voltage U0 (Inline potentials) | 3.3 V |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Protection class (Electrical isolation) | III, IEC 61140, EN 61140, VDE 0140-1 |
| Bridge difference Ud (Inline potentials) | Measuring range specified by selecting the characteristic and the bridge voltage |
| Connection technology (Inline potentials) | 6 or 4-wire, twisted pair shielded cable |
| Diagnostics messages (Ambient conditions) | Failure of the power supply at UANAError message in the process data |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Description of the input (Inline potentials) | Input channels for strain gauge |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 10 % ... 95 % (non-condensing) |
| Utilization restriction (Key Commercial Data) | 1 |
| Measured value representation (Inline potentials) | 15 bit + sign bit |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Permissible humidity (storage/transport) (Dimensions) | 10 % ... 95 % (non-condensing) |
| Connection in acc. with standard (Electrical isolation) | CUL |
Technical specifications and performance data
Installation and operation guide