| Parameter | Value |
|---|---|
| Failure of or insufficient communications power ULI/O error message sent to the bus coupler | |
| Depth | 71.5 mm |
| Logic | PSa- PSbconnected = Parameter locked |
| Width | 48.8 mm |
| Height | 120 mm |
| Network | Yes |
| Quantity | 1 (PSa- PSb) |
| Impedance | > 55 Ω |
| Addressing | Address 0 = Broadcast, alternating display of measured gross/net value and measured tare value |
| Net weight | 160 g |
| Description | Lock of parameters |
| Designation | Inline local bus |
| Mounting type | DIN rail |
| Operating mode | Process data operation with 2 words, PCP with 2 words |
| Output current | max. 90 mA |
| Output voltage | typ. 5 V ±2 % |
| Characteristics | ±1 mV/V, ±2 mV/V, ±3 mV/V, ±3.33 mV/V, ±4 mV/V, ±5 mV/V |
| Fieldbus system | Lokalbus |
| Number of inputs | 1 |
| Bridge voltage U0 | 5 V |
| Connection method | Inline data jumper |
| Number of outputs | 1 |
| Power consumption | typ. 1 W (Device in nominal operation) |
| Note on dimensions | Dimensions with covering hood |
| Output description | Voltage output |
| Transmission speed | 500 kBit/s |
| Type of protection | Short-circuit protection of the voltage outputs |
| Process data update | typ. 100 ms |
| Bridge difference Ud | Measuring range specified by selecting the characteristic |
| Degree of protection | IP20 |
| Diagnostics messages | Failure of the power supply at UANAError message in the process data |
| Termination resistor | 120 Ω |
| Transmission protocol | STX/ETX |
| Typical response time | < 100 ms |
| Maximum output current | max. 90 mA |
| Communications power UL | 7.5 V DC |
| I/O supply voltage UANA | 24 V DC |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Description of the input | Input channel for strain gauge |
| Current consumption from UL | typ. 80 mA |
| Protective circuit/component | Yes, at least 1 minute through temperature monitoring |
| Current consumption from UANA | max. 50 mA |
| Measured value representation | Process data: status bits and measured value including decimal places of the gross/net display |
| Ambient temperature (operation) | -25 °C ... 55 °C (Type approval according to DIN EN 45501 and OIML R76: -10°C ... 40°C) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |