| Parameter | Value |
|---|---|
| GTIN | 4017918946920 |
| Orderkey | 2863627 |
| Catalog page | Page 207 (C-8-2015) |
| Depth (Note) | 71.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 24.4 mm |
| (Interfaces) | max. 260 mA (all connections of the serial interface are short-circuited) |
| Height (Note) | 136.8 mm |
| Country of origin | DE (Germany) |
| Data bits (General) | 7 or 8 |
| Interface (General) | RS-422/-485 |
| Stop bits (General) | 1 or 2 |
| Custom tariff number | 85389091 |
| Designation (General) | Inline local bus |
| Input buffer (General) | 4 kByte |
| Output buffer (General) | 1 kByte |
| Designation (Dimensions) | Inline connector |
| Designation (Interfaces) | Communications power (UL) |
| Dimensional drawing (Note) | |
| Parity (Inline potentials) | Even, odd or no parity |
| Connection method (General) | Spring-cage connection |
| Supply voltage (Interfaces) | 7.5 V DC (via voltage jumper) |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Transmission speed (General) | 500 kbps |
| Stripping length (Dimensions) | 8 mm |
| (Serial input/output channel) | 24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min. |
| Connection method (Dimensions) | Spring-cage connection |
| Transmission physics (General) | Copper |
| Net weight (Ambient conditions) | 135 g |
| Current consumption (Interfaces) | typ. 170 mA |
| Mounting type (Ambient conditions) | DIN rail |
| Weight per Piece (excluding packing) | 135.000 g |
| Transmission type (Inline potentials) | Transparent mode, end-end mode, dual buffer mode, 3964R, XON/XOFF, MOVILINK protocol |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Degree of protection (Connection data) | IP20 |
| Protection class (Electrical isolation) | III, IEC 61140, EN 61140, VDE 0140-1 |
| Test section (Serial input/output channel) | 5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min. |
| Conductor cross section AWG max. (Dimensions) | 16 |
| Conductor cross section AWG min. (Dimensions) | 28 |
| Utilization restriction (Key Commercial Data) | 1 |
| Conductor cross section solid max. (Dimensions) | 1.5 mm² |
| Conductor cross section solid min. (Dimensions) | 0.08 mm² |
| Ambient temperature (operation) (Connection data) | -25 °C ... 55 °C |
| Conductor cross section flexible max. (Dimensions) | 1.5 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.08 mm² |
| Permissible humidity (operation) (Connection data) | 75 % ... 85 % (in the range of -25°C ... +55°C, appropriate measures against increased humidity (> 85%) must be taken.) |
| Connection in acc. with standard (Electrical isolation) | CUL |
| Ambient temperature (storage/transport) (Connection data) | -25 °C ... 85 °C |
| Permissible humidity (storage/transport) (Connection data) | 75 % ... 85 % (Slight temporary condensation may sometimes appear on the housing, e.g. when the terminal block is brought out of a vehicle into an enclosed room.) |
Technical specifications and performance data
Installation and operation guide