Key Specifications
:30 V DC (maximum)
Type:modular
Depth:71.5 mm
Width:24.4 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
30 V DC (maximum)
Typemodular
Depth71.5 mm
Width24.4 mm
Height135 mm
Input nameCounter input for 24 V signals
DesignationPower supply for sensors
Output nameSwitching output
Current drawmax. 50 mA
Product typeI/O component
ID code (hex)BF
Input currenttyp. 5 mA
Input voltage24 V DC (Nominal voltage)
Mounting typeDIN rail mounting
ID code (dec.)191
Operating modeEvent counting, frequency/time measurement
Output currentmax. 0.5 A (Nominal current)
Output voltage24 V DC (Nominal voltage)
Product familyInline
Supply voltage7.5 V DC (via voltage jumper)
Connection nameInline connector
Input frequencymax. 100 kHz
Register length4 Byte
Article revision01
Input resistanceapprox. 5.7 kΩ
Number of inputs1 (only one counter input can be used, either for 24 V or for 5 V signals)
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)
Stripping length8 mm
Connection methodInline data jumper
Length code (dec)02
Length code (hex)02
Number of outputs1
Power consumptionmax. 0.375 W (at UL)
Scope of deliveryincluding Inline connectors and marking fields
Input address area4 Byte
Nominal load, lampmax. 12 W
Protective circuitShort-circuit protection; Yes, short-circuit-proof (automatically switched on again)
Special propertiesExtreme conditions version
Transmission speed500 kbps
Dimensional drawing
Nominal load, ohmicmax. 12 W (48 Ω)
Note on applicationOnly for industrial use
Output address area4 Byte
Degree of protectionIP20
Diagnostics messagesSensor supply short-circuit
Number of interfaces2
Process data channel32 bit
Transmission physicsCopper
Connection technology2-, 3-conductor
Overcurrent shut-downmin. 0.7 A
Nominal load, inductivemax. 12 VA (1.2 H, 48 Ω)
Required parameter data1 Byte
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section AWG28 ... 16
Required configuration data5 Byte
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Ambient temperature (operation)-25 °C ... 55 °C (Standard)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Behavior with inductive overloadOutput can be destroyed
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Behavior in the event of lamp overloadAuto restart after eliminating the overload
Ambient temperature (storage/transport)-40 °C ... 85 °C
Behavior in the event of ohmic overloadAuto restart after eliminating the overload
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Reverse voltage resistance to short pulsesReverse voltage proof
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic)/functional ground500 V AC, 50 Hz, 1 min.

Product Description

Inline counter module in the variant for extreme conditions, complete with accessories (connectors and marking surfaces), 1 meter input, 1 control input, 1 output, 24 VDC, 500 mA, 3-wire connection te
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty