| Parameter | Value |
|---|---|
| GTIN | 4046356639965 |
| Orderkey | 2700775 |
| Catalog page | Page 167 (C-6-2017) |
| Depth (Note) | 71.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 12.2 mm |
| (Interfaces) | max. 75 mA (Nominal current load (IOUT1/2= 20 mA, RL= 0 Ω)) |
| Height (Note) | 119.8 mm |
| (Analog outputs) | 24 V analog supply (analog I/O) / functional earth ground 500 V AC 50 Hz 1 min. |
| Country of origin | DE (Germany) |
| (Inline potentials) | -10 V ... 10 V |
| Custom tariff number | 85389091 |
| (Ambient conditions) | Configuration invalid Message in the diagnostic code (in the IB IL format) |
| Designation (General) | Inline local bus |
| Designation (Interfaces) | Supply of analog modules (UANA) |
| No. of channels (General) | 2 |
| Note on dimensions (Note) | Housing dimensions |
| Dimensional drawing (Note) | |
| Connection method (General) | Inline data jumper |
| Supply voltage (Interfaces) | 24 V DC (via voltage jumper) |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Transmission speed (General) | 500 kbps |
| Precision (Inline potentials) | typ. 0.1 % (of output range final value) |
| Test section (Analog outputs) | 7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC 50 Hz 1 min. |
| Power consumption (Interfaces) | typ. 1.32 W (Nominal voltage load (UOUT1/2= 10 V, RL= 1 kΩ)) |
| Transmission physics (General) | Copper |
| Net weight (Ambient conditions) | 66 g |
| Output name (Inline potentials) | Analog outputs |
| Current consumption (Interfaces) | typ. 24 mA (No-load) |
| Data formats (Inline potentials) | IB IL, S7-compatible |
| Degree of protection (Dimensions) | IP20 |
| Supply voltage range (Interfaces) | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| D/A resolution (Inline potentials) | 12 bit |
| Mounting type (Ambient conditions) | DIN rail |
| Weight per Piece (excluding packing) | 66.000 g |
| Air pressure (operation) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Number of outputs (Inline potentials) | 2 |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Type of protection (Inline potentials) | Short-circuit and overload protection |
| D/A conversion time (Inline potentials) | typ. 10 µs |
| Process data update (Inline potentials) | bus-synchronous |
| Protection class (Electrical isolation) | III, IEC 61140, EN 61140, VDE 0140-1 |
| Connection technology (Inline potentials) | 2-wire |
| Current output signal (Inline potentials) | 0 mA ... 20 mA |
| Diagnostics messages (Ambient conditions) | Failure of the internal I/O supply I/O error message sent to the bus coupler |
| Voltage output signal (Inline potentials) | 0 V ... 10 V |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Permissible cable length (Inline potentials) | max. 250 m (The specifications refer to nominal operation after complying with installation instructions. The specifications refer to the following reference cable type: Shielded power station cable: LiYCY; 2 x 2 x 0,5 mm²; VDE0812) |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Utilization restriction (Key Commercial Data) | 1 |
| Protective circuit/component (Inline potentials) | Electronic |
| Note on weight specifications (Ambient conditions) | with connector |
| Load/output load current output (Inline potentials) | ≤ 450 Ω |
| Load/output load voltage output (Inline potentials) | > 1 kΩ |
| Representation of output values (Inline potentials) | 12 bits (11 bits + sign bit) |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Permissible humidity (storage/transport) (Dimensions) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Note regarding the connection technology (Inline potentials) | shielded |