| Parameter | Value |
|---|---|
| typ. 68 mA | |
| Depth | 71.5 mm |
| Width | 48.8 mm |
| Height | 136.8 mm |
| Input name | Analog inputs |
| Net weight | 213 g |
| Designation | Inline local bus |
| Data formats | IL, IB ST, IB RT, standardized representation, PIO format |
| Mounting type | DIN rail |
| Fieldbus system | Lokalbus |
| Number of inputs | max. 8 (single ended) |
| Connection method | Inline data jumper |
| Note on dimensions | Housing dimensions |
| Transmission speed | 2 MBit/s |
| A/D conversion time | approx. 10 µs |
| Measuring principle | Successive approximation |
| Current input signal | 0 mA ... 20 mA |
| Degree of protection | IP20 |
| Transmission physics | Copper |
| Voltage input signal | 0 V ... 5 V |
| Limit frequency (3 dB) | 3.5 kHz |
| Communications power UL | 7.5 V DC (via voltage jumper) |
| I/O supply voltage UANA | 24 V DC |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Measured value resolution | 16 bits (15 bits + sign bit) |
| Current consumption from UL | max. 85 mA |
| Current consumption from UANA | max. 38 mA |
| Measured value representation | 16 bit two's complement |
| Note on weight specifications | with connectors |
| Input resistance current input | 25 Ω 0.01 % |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Input resistance of voltage input | > 240 kΩ 0.01 % |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Technical specifications and performance data
Installation and operation guide