| Parameter | Value |
|---|---|
| 4 mA ... 20 mA | |
| Data format | IB IL, IB ST, IB RT, normalized representation |
| Construction | modulate |
| Product Type | I/O Component |
| Product Family | Inline |
| Connection type | Inline shielded connector |
| Measuring System | Successive approach |
| Protection Index | IP20 |
| Type of mounting | DIN rail mounting |
| Number of Entries | 2 |
| Scope of delivery | including Inline connector and marking surface |
| Denomination Entry | Analog inputs |
| Ticket Description | Single Ended, Voltage or Current Inputs |
| Transmission speed | 500 kBit/s |
| A/D Conversion Time | approx. 120 μs (per channel) |
| Input Signal Current | 0 mA ... 20 mA |
| Input Signal Voltage | 0 V ... 10 V |
| Transmission Physics | copper |
| AWG Conductor Section | 28 ... 16 |
| Connection technology | 2 conductors |
| Limit frequency (3 dB) | 40 Hz |
| Denomination Connection | Inline Connectors |
| Rigid conductor section | 0.08 mm² ... 1.5 mm² |
| A/D converter resolution | 16 Bit |
| A note on the application | For industrial use only |
| Length to be de-insulated | 8 mm |
| Flexible conductor section | 0.08 mm² ... 1.5 mm² |
| Input Resistor Current Input | 50 Ω |
| Measurement value resolution | 16 bits (15 bits + sign) |
| Input Resistance Voltage Input | > 220 kΩ |
| A Note on Connection Technology | shielded |
| Representation of the measured value | 16-bit complement to two |
| Maximum Dissipated Power with Nominal Condition | 1.87 W |
Technical specifications and performance data