| Parameter | Value |
|---|---|
| GTIN | 4017918168490 |
| Orderkey | 2727378 |
| (General) | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 10g, evaluation criterion 1 |
| Catalog page | Page 186 (C-6-2017) |
| Depth (Note) | 109 mm |
| Packing unit | 1 pc |
| Width (Note) | 63 mm |
| Height (Note) | 224 mm |
| Country of origin | DE (Germany) |
| Note (Dimensions) | Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector |
| (Mains connection) | 1 |
| (Inline potentials) | Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module |
| Custom tariff number | 85389091 |
| Designation (Interfaces) | Mains connection |
| Note (Inline potentials) | Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector |
| Number (Mains connection) | 1 (3 phases, short-circuit-proof with external conductor protection 16 A (full-range fuse for semiconductors, type gR)) |
| Number (Motor monitoring) | 1 |
| Dimensional drawing (Note) | |
| Mechanical tests (General) | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 2g, evaluation criterion 1 |
| Protection class (General) | I, IEC 61140, EN 61140, VDE 0140-1 |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Connection method (Interfaces) | Power plug |
| Designation (Motor monitoring) | Brake module (external) |
| Net weight (Inline potentials) | 500 g |
| Operating voltage (Interfaces) | 187 V AC ... 440 V AC +0 % (conductor voltage) |
| Output name (Mains connection) | Motor output |
| Designation (Ambient conditions) | Inline local bus |
| Number of positions (Interfaces) | 5 |
| Degree of protection (Dimensions) | IP20 |
| Mounting type (Inline potentials) | DIN rail |
| Switching rate (Mains connection) | Max. 30 per minute (observe derating) |
| Designation (Motor starter, brake) | Segment circuit supply (US) |
| Frequency range (Mains connection) | 50 Hz ... 60 Hz |
| Operating mode (Inline potentials) | Process data mode with one byte |
| Type of contact (Motor monitoring) | Solid-state contact |
| Connection method (Mains connection) | COMBICON |
| No. of channels (Ambient conditions) | 2 |
| Operating voltage (Mains connection) | 200 V AC ... 440 V AC |
| Weight per Piece (excluding packing) | 500.000 g |
| Air pressure (operation) (Dimensions) | 70 kPa ... 106 kPa (up to 2000 m above sea level) |
| Supply voltage (Motor starter, brake) | 24 V DC (via voltage jumper) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Connection method (Ambient conditions) | Inline data jumper |
| Number of positions (Mains connection) | 4 |
| Transmission speed (Ambient conditions) | 500 kbps |
| Connection technology (Motor monitoring) | COMBICON |
| Diagnostics messages (Inline potentials) | Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module |
| Nominal current range (Mains connection) | 0.2 A ... 3.6 A |
| Power consumption (Motor starter, brake) | max. 1.2 W (entire device) |
| Assembly instructions (Inline potentials) | To safeguard sufficient ventilation, ensure that there is an installation clearance of a minimum of 50 cm both above and below. |
| Designation connection point (Interfaces) | Terminal strip X11 and X12 |
| Transmission physics (Ambient conditions) | Copper |
| Current consumption (Motor starter, brake) | max. 50 mA |
| Overspeed tripping (Motor starter, output) | ≥ 20 A (after 0.3 seconds) |
| Max. current carrying capacity (Interfaces) | 20 A |
| Supply voltage range (Motor starter, brake) | 19.2 V DC ... 28.8 V DC (including all tolerances, including ripple) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 10 % ... 85 % (non-condensing) |
| Utilization restriction (Key Commercial Data) | 1 |
| Parameterization range (Motor starter, output) | 0.2 A ... 3.6 A (steps of 50/100/200 mA, via fieldbus) |
| Designation connection point (Mains connection) | Terminal strip X10 |
| Permissible conductor cross section (Interfaces) | max. 2.5 mm² (L1, L2, L3, N, PE (not leading)) |
| Note on weight specifications (Inline potentials) | without plug |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Permissible humidity (storage/transport) (Dimensions) | 10 % ... 85 % (non-condensing) |
| Permissible conductor cross section (Mains connection) | 1 mm² ... 2.5 mm² |
Technical specifications and performance data