| Parameter | Value |
|---|---|
| GTIN | 4017918894306 |
| Orderkey | 2861360 |
| Catalog page | Page 165 (C-6-2017) |
| Depth (Note) | 71.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 12.2 mm |
| Height (Note) | 119.8 mm |
| (Analog outputs) | Thermistor / all other areas 1200 V AC 50 Hz 1 min. |
| Country of origin | DE (Germany) |
| (Inline potentials) | 50 Ω ... 2.25 kΩ (Operating range, total resistance) |
| Custom tariff number | 85389091 |
| Designation (General) | Inline local bus |
| Designation (Interfaces) | Segment circuit supply (US) |
| Dimensional drawing (Note) | |
| Connection method (General) | Inline data jumper |
| Supply voltage (Interfaces) | 24 V DC (via voltage jumper) |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Transmission speed (General) | 500 kbps |
| Test section (Analog outputs) | 5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min. |
| Input name (Inline potentials) | Resistance sensor |
| Power consumption (Interfaces) | max. 12 W (For R = 12 Ω, L = 1.2 H/48 Ω) |
| Transmission physics (General) | Copper |
| Net weight (Ambient conditions) | 50 g |
| Current consumption (Interfaces) | max. 500 mA |
| Connection method (Analog inputs) | Spring-cage connection |
| Degree of protection (Dimensions) | IP20 |
| Number of outputs (Analog inputs) | 1 |
| Supply voltage range (Interfaces) | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Mounting type (Ambient conditions) | DIN rail |
| Type of protection (Analog inputs) | Short-circuit and overload proof |
| Number of inputs (Inline potentials) | 1 |
| Weight per Piece (excluding packing) | 50.000 g |
| Air pressure (operation) (Dimensions) | 80 kPa ... 106 kPa (up to 2000 m above sea level) |
| Connection method (Inline potentials) | Spring-cage connection |
| Connection technology (Analog inputs) | 2-wire |
| Current output signal (Analog inputs) | 500 mA (per output) |
| Input filter time (Inline potentials) | typ. 10 ms |
| Voltage output signal (Analog inputs) | 24 V DC (US- 1 V) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Protection class (Electrical isolation) | III, IEC 61140, EN 61140, VDE 0140-1 |
| Connection technology (Inline potentials) | 2-wire |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Description of the input (Inline potentials) | Input for PTC thermistor |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | -25 % ... 55 % (75% average, 85% seldom) |
| Utilization restriction (Key Commercial Data) | 1 |
| Load/output load voltage output (Analog inputs) | < 2.7 kΩ (Total resistance for output signal HIGH) |
| Note on weight specifications (Ambient conditions) | without plug |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Linear resistance measuring range (Inline potentials) | 2.7 kΩ ... 3.5 kΩ (Shutdown range, total resistance) |
| Permissible humidity (storage/transport) (Dimensions) | -25 % ... 85 % |
| Sensor types (RTD) that can be used (Inline potentials) | PTC thermistor according to DIN 44081 or DIN 44082 |
| Nominal value of the current sources (Inline potentials) | max. 1.2 mA (For non-load voltage of < 8 V DC) |
Technical specifications and performance data
Installation and operation guide