| Parameter | Value |
|---|---|
| 2, 3, 4-wire | |
| Depth | 71.5 mm |
| Width | 48.8 mm |
| Height | 119.8 mm |
| Net weight | 245.6 g |
| Designation | Inline local bus |
| Output name | Digital outputs |
| Mounting type | DIN rail |
| Output current | max. 6 A (Total current of all outputs, -25 °C ... 50 °C) |
| Output voltage | 24 V DC (US- 1 V) |
| Supply voltage | 24 V DC (via voltage jumper) |
| Fieldbus system | INTERBUS |
| Connection method | Inline data jumper |
| Number of outputs | 4 (with two-channel assignment) |
| Nominal load, lamp | see safety data |
| Note on dimensions | Housing dimensions |
| Protective circuit | Overload protection, short-circuit protection of outputs |
| Transmission speed | 500 kBit/ / 2 MBit/s (can be switched) |
| Current consumption | max. 230 mA (from the local bus) |
| Nominal load, ohmic | see safety data |
| Degree of protection | IP20 |
| Diagnostics messages | Short-circuit / overload of the digital outputs Error message in diagnostics code (bus) and display by means of the LED on the motor |
| Supply voltage range | 19.2 V DC ... 30 V DC |
| Main circuit supply UM | 24 V DC |
| Nominal output voltage | 24 V DC |
| Communications power UL | 7.5 V (via voltage jumper) |
| Nominal load, inductive | see safety data |
| Supply voltage range UM | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) |
| Current consumption from UL | max. 230 mA (see safety data) |
| Current consumption from UM | typ. 30 mA (all outputs set including actuator current) |
| Note on weight specifications | with connectors |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above mean sea level) |
| Category according to EN 13849-1 | 4 |
| Maximum output current per group | 3 A |
| Permissible humidity (operation) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
| Maximum output current per module | 3 A (See technical data) |
| Maximum output current per channel | 2 A |
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Permissible humidity (storage/transport) | 10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.) |
Technical specifications and performance data