| Parameter | Value |
|---|---|
| GTIN | 4046356981781 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2702133 |
| Catalog page | Page 155 (C-6-2017) |
| Depth (Note) | 71.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 12.2 mm |
| (Dimensions) | -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) |
| (Interfaces) | 0 A |
| Height (Note) | 119.8 mm |
| Country of origin | DE (Germany) |
| (Digital outputs) | 7.5 V supply (bus logics) / functional earth ground 500 V AC 50 Hz 1 min. |
| Custom tariff number | 85389099 |
| Designation (General) | Inline local bus |
| Designation (Interfaces) | Segment circuit supply (US) |
| No. of channels (General) | 2 |
| Note on dimensions (Note) | Housing dimensions |
| Dimensional drawing (Note) | |
| Connection method (General) | Inline data jumper |
| Supply voltage (Interfaces) | 24 V DC (via voltage jumper) |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Net weight (Connection data) | 61 g |
| Transmission speed (General) | 500 kbps |
| Power consumption (Interfaces) | max. 0.27 W |
| Test section (Digital outputs) | 7.5 V supply (bus logics)/24 V supply (I/O) 500 V AC 50 Hz 1 min. |
| Mounting type (Connection data) | DIN rail |
| Output name (Inline potentials) | Digital outputs |
| Current consumption (Interfaces) | max. 4 A |
| Designation (Ambient conditions) | Inline connector |
| Operating mode (Connection data) | Process data mode with 2 bits |
| Degree of protection (Dimensions) | IP20 |
| Supply voltage range (Interfaces) | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Output voltage (Inline potentials) | 24 V DC (US- 1 V) |
| Weight per Piece (excluding packing) | 61.000 g |
| Air pressure (operation) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Connection method (Inline potentials) | Spring-cage connection |
| Number of outputs (Inline potentials) | 2 |
| Stripping length (Ambient conditions) | 8 mm |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Connection method (Ambient conditions) | Spring-cage connection |
| Diagnostics messages (Connection data) | Short-circuit / overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module |
| Nominal load, lamp (Inline potentials) | 48 W |
| Type of protection (Inline potentials) | Overload protection, short-circuit protection of outputs |
| Nominal load, ohmic (Inline potentials) | 48 W (12 Ω) |
| Protection class (Electrical isolation) | III, IEC 61140, EN 61140, VDE 0140-1 |
| Connection technology (Inline potentials) | 4-wire |
| Nominal output voltage (Inline potentials) | 24 V DC |
| Nominal load, inductive (Inline potentials) | 48 VA (1,2 H, 12 Ω) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 10 % ... 95 % (non-condensing) |
| Utilization restriction (Key Commercial Data) | 1 |
| Note on weight specifications (Connection data) | with connector |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Conductor cross section AWG max. (Ambient conditions) | 16 |
| Conductor cross section AWG min. (Ambient conditions) | 28 |
| Maximum output current per module (Inline potentials) | 4 A |
| Permissible humidity (storage/transport) (Dimensions) | 10 % ... 95 % (non-condensing) |
| Maximum output current per channel (Inline potentials) | 2 A |
| Conductor cross section solid max. (Ambient conditions) | 1.5 mm² |
| Conductor cross section solid min. (Ambient conditions) | 0.08 mm² |
| Connection in acc. with standard (Electrical isolation) | CUL |
| Conductor cross section flexible max. (Ambient conditions) | 1.5 mm² |
| Conductor cross section flexible min. (Ambient conditions) | 0.08 mm² |
Technical specifications and performance data