| Parameter | Value |
|---|---|
| 0 A | |
| Type | modular |
| Depth | 71.5 mm |
| Width | 12.2 mm |
| Height | 119.8 mm |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
| Input name | Digital inputs |
| Current draw | max. 40 mA |
| Product type | I/O component |
| ID code (hex) | BE |
| Input voltage | 24 V DC |
| Mounting type | DIN rail mounting |
| ID code (dec.) | 190 |
| Operating mode | Process data operation with 4 bits |
| Product family | Inline |
| Supply voltage | 7.5 V DC (via voltage jumper) |
| Connection name | Inline connector |
| No. of channels | 4 |
| Register length | 4 bit |
| Article revision | 09 |
| Number of inputs | 4 |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Stripping length | 8 mm |
| Connection method | Inline data jumper |
| Length code (dec) | 65 |
| Length code (hex) | 41 |
| Scope of delivery | including Inline connector and labeling field |
| Input address area | 4 bit |
| Transmission speed | 500 kbps |
| Dimensional drawing | |
| Input voltage range | -30 V DC ... 30 V DC |
| Note on application | Only for industrial use |
| Output address area | 0 bit |
| Degree of protection | IP20 |
| Number of interfaces | 2 |
| Process data channel | 0 bit |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Transmission physics | Copper |
| Connection technology | 3-conductor |
| Typical response time | < 1 ms |
| Required parameter data | 1 Byte |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Description of the input | EN 61131-2 type 1 |
| Nominal input voltage UIN | 24 V DC |
| Sensor current per channel | max. 250 mA |
| Conductor cross section AWG | 28 ... 16 |
| Required configuration data | 4 Byte |
| Nominal input current at UIN | min. 3 mA (at nominal voltage) |
| Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
| Input voltage range "0" signal | -3 V DC ... 5 V |
| Input voltage range "1" signal | 15 V DC ... 30 V DC |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Maximum power dissipation for nominal condition | 0.6 W |
| Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O) | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 7.5 V supply (bus logic)/functional ground | 500 V AC, 50 Hz, 1 min. |
Technical specifications and performance data