| Parameter | Value |
|---|---|
| max. 30 V AC (PELV (EN 61131)) | |
| Type | modular |
| Depth | 71.5 mm |
| Width | 12.2 mm |
| Height | 119.8 mm |
| Current draw | max. 30 mA |
| Product type | I/O component |
| ID code (hex) | BD |
| Mounting type | DIN rail mounting |
| ID code (dec.) | 189 |
| Operating mode | Process data mode with 2 bits |
| Product family | Inline |
| Supply voltage | 7.5 V DC (via voltage jumper) |
| Connection name | Inline connector |
| No. of channels | 2 |
| Register length | 2 bit |
| Article revision | 05 |
| Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Stripping length | 8 mm |
| Connection method | Inline data jumper |
| Length code (dec) | 194 |
| Length code (hex) | C2 |
| Number of outputs | 2 (floating) |
| Scope of delivery | including Inline connector and labeling field |
| Switching current | min. 10 µA |
| Switching voltage | min. 10 mV (DC) |
| Input address area | 0 bit |
| Note on dimensions | Housing dimensions |
| Special properties | for switching ohmic loads |
| Switching capacity | 60 W |
| Transmission speed | 500 kbps |
| Dimensional drawing | |
| Note on application | Only for industrial use |
| Output address area | 2 bit |
| Degree of protection | IP20 |
| Number of interfaces | 2 |
| Overvoltage category | II (IEC 60664-1, EN 60664-1) |
| Process data channel | 2 bit |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Contact switching type | Changeover contact |
| Mechanical service life | 2x 105cycles |
| Required parameter data | 3 Byte |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Conductor cross section AWG | 28 ... 16 |
| Limiting continuous current | 2 A (at maximum ambient temperature) |
| Required configuration data | 4 Byte |
| Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
| Test voltage: Contact/contact | 1 kV, 50 Hz, 1 min. |
| Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Test voltage: Contact/functional ground | 1 kV, 50 Hz, 1 min. |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
| Test voltage: Relay contact / Bus logics | 1.5 kV, 50 Hz, 1 min. |
| Maximum power dissipation for nominal condition | 0.8 W |
Technical specifications and performance data
Installation and operation guide