| Parameter | Value |
|---|---|
| GTIN | 4055626807249 |
| Orderkey | 1081099 |
| (Drawings) | |
| Packing unit | 1 |
| Pitch (Drawings) | 5 mm |
| ETIM 4.0 (eCl@ss) | EC001031 |
| ETIM 5.0 (eCl@ss) | EC002638 |
| ETIM 6.0 (eCl@ss) | EC002638 |
| ETIM 7.0 (eCl@ss) | EC002638 |
| UNSPSC 13.2 (ETIM) | 39121409 |
| UNSPSC 18.0 (ETIM) | 39121409 |
| UNSPSC 19.0 (ETIM) | 39121409 |
| UNSPSC 20.0 (ETIM) | 39121409 |
| UNSPSC 21.0 (ETIM) | 39121409 |
| Custom tariff number | 85366990 |
| (Ambient conditions) | Test passed |
| Result (Pull-out test) | Test passed |
| Note (Connection capacity) | WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201 |
| Type of contact (Drawings) | Female connector |
| Connection method (Drawings) | Push-in spring connection |
| Note (Packaging information) | Refer to the data sheet for the range in the download area. |
| eCl@ss 4.0 (Classifications) | 27260700 |
| eCl@ss 4.1 (Classifications) | 27260700 |
| eCl@ss 5.0 (Classifications) | 27260700 |
| eCl@ss 5.1 (Classifications) | 27260700 |
| eCl@ss 6.0 (Classifications) | 27260700 |
| eCl@ss 7.0 (Classifications) | 27440309 |
| eCl@ss 8.0 (Classifications) | 27440309 |
| eCl@ss 9.0 (Classifications) | 27440309 |
| No. of cycles (Pull-out test) | 25 |
| Specification (Pull-out test) | IEC 60512-15-1:2008-05 |
| Nom. voltage (Item properties) | 300 V |
| Number of positions (Drawings) | 2 |
| Dimensional test (Pull-out test) | Test passed IEC 60512-1-2:2002-02 |
| Test result (Ambient conditions) | Test passed |
| pluggable (Electrical parameters) | Yes |
| Cold stress (Durability tests (B)) | -40 °C/2 h |
| Specification (Climatic tests (D)) | IEC 61984:2008-10 |
| Test specification (Pull-out test) | IEC 61984 |
| Visual examination (Pull-out test) | Test passed IEC 60512-1-1:2002-02 |
| Test force per pos. (Pull-out test) | 20 N |
| (Termination and connection method) | 2.5 mm² / flexible / > 50 N |
| Brief article description (Drawings) | Printed-circuit board connector |
| Specification (Durability tests (B)) | ISO 6988:1985-02 |
| Specification (Mechanical tests (A)) | IEC 60512-9-1:2010-03 |
| Type of note (Packaging information) | Assembly instruction: |
| Resistance of marking (Pull-out test) | Test passed IEC 60068-2-70:1995-12 |
| Thermal stress (Durability tests (B)) | 100 °C/168 h |
| Contact material (Connection capacity) | Cu alloy |
| Corrosive stress (Durability tests (B)) | 0.2 dm3SO2on 300 dm3/40 °C/1 cycle |
| Polarization and coding (Pull-out test) | Test passed IEC 60512-13-5:2006-02 |
| Stripping length (Electrical parameters) | 10 mm |
| (Environmental and durability tests (E)) | • Operate the connector only when it is fully plugged in. |
| Connection method (Electrical parameters) | Push-in spring connection |
| Pitch (Material data – actuating element) | 5 mm |
| Contact resistance R1 (Mechanical tests (A)) | 1.7 mΩ |
| Contact resistance R2 (Mechanical tests (A)) | 1.9 mΩ |
| Insulating material (Material data - contact) | PA |
| Insulating material (Material data - housing) | PBT |
| Surface characteristics (Connection capacity) | Tin-plated |
| Conductor connection test (Ambient conditions) | The stripped-off ends of the largest conductor can be completely inserted in the opening of the terminal point without using excessive force. |
| Pieces per package (Dimensions for the product) | 50 |
| Pull-out test (Termination and connection method) | IEC 60999-1:1999-11 |
| Width [ w ] (Material data – actuating element) | 18.8 mm |
| Height [ h ] (Material data – actuating element) | 21.6 mm |
| Insertion/withdrawal cycles (Mechanical tests (A)) | 25 |
| Length [ l ] (Material data – actuating element) | 10.9 mm |
| Withdraw strength per pos. approx. (Pull-out test) | 3 N |
| Insertion strength per pos. approx. (Pull-out test) | 4 N |
| Insulating material group (Material data - contact) | I |
| CTI according to IEC 60112 (Material data - contact) | 600 |
| CTI according to IEC 60112 (Material data - housing) | 275 |
| Safety note (Environmental and durability tests (E)) | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
| Conductor cross section solid (Electrical parameters) | 0.2 mm² ... 1.5 mm² |
| Specification (Air clearances and creepage distances) | IEC 61984 |
| Specification (Mechanical tests according to standard) | IEC 60664-1:2007-04 |
| Denomination packing units (Dimensions for the product) | Pcs. |
| Conductor cross section flexible (Electrical parameters) | 0.2 mm² ... 2.5 mm² |
| Power-frequency withstand voltage (Durability tests (B)) | 1.39 kV |
| Power-frequency withstand voltage (Mechanical tests (A)) | 2.21 kV |
| Cylindrical gauge a x b / diameter (Electrical parameters) | 2.4 mm x 1.5 mm / 1.9 mm |
| Result, degree of protection, IP code (Climatic tests (D)) | Finger safety with IP20 test finger |
| Conductor cross section AWG / kcmil (Electrical parameters) | 24 ... 16 |
| Ambient temperature (assembly) (General product information) | -5 °C ... 100 °C |
| Metal surface contact area (top layer) (Connection capacity) | Tin (4 - 8 µm Sn) |
| Ambient temperature (operation) (General product information) | -40 °C ... 105 °C (depending on power dissipation) |
| Impulse withstand voltage at sea level (Durability tests (B)) | 4.8 kV |
| Impulse withstand voltage at sea level (Mechanical tests (A)) | 4.8 kV |
| Test for conductor damage and slackening (Ambient conditions) | IEC 60999-1:1999-11 |
| Test – repeated connection and release (Ambient conditions) | IEC 60999-1:1999-11 |
| Metal surface terminal point (top layer) (Connection capacity) | Tin (4 - 8 µm |
| Flammability rating according to UL 94 (Material data - contact) | V0 |
| Flammability rating according to UL 94 (Material data - housing) | V0 |
| Test specification (Current carrying capacity / derating curves) | IEC 61984 |
| Insulation resistance, neighboring positions (Mechanical tests (A)) | > 1.9 TΩ |
| Rated surge voltage (II/2) (Mechanical tests according to standard) | 4 kV |
| Rated surge voltage (III/2) (Mechanical tests according to standard) | 4 kV |
| Rated surge voltage (III/3) (Mechanical tests according to standard) | 4 kV |
| Ambient temperature (storage/transport) (General product information) | -40 °C ... 55 °C |
| Rated insulation voltage (II/2) (Mechanical tests according to standard) | 600 V |
| Connection in acc. with standard (Environmental and durability tests (E)) | EN-VDE |
| Rated insulation voltage (III/2) (Mechanical tests according to standard) | 300 V |
| Rated insulation voltage (III/3) (Mechanical tests according to standard) | 250 V |
| Clearances and creepage distances (Mechanical tests according to standard) | IEC 60664-1:2007-04 |
| Flammability rating according to UL 94 (Environmental and durability tests (E)) | V0 |
| Minimum creepage distance value (II/2) (Mechanical tests according to standard) | 3.2 mm |
| Minimum creepage distance value (III/2) (Mechanical tests according to standard) | 3 mm |
| Minimum creepage distance value (III/3) (Mechanical tests according to standard) | 3.2 mm |
| Withdraw strength per pos. approx. (Current carrying capacity / derating curves) | 3 N |
| Insertion strength per pos. approx. (Current carrying capacity / derating curves) | 4 N |
| Minimum clearance - inhomogeneous field (II/2) (Mechanical tests according to standard) | 3 mm |
| Minimum clearance - inhomogeneous field (III/2) (Mechanical tests according to standard) | 3 mm |
| Minimum clearance - inhomogeneous field (III/3) (Mechanical tests according to standard) | 3 mm |
| Contact holder in insert requirements >20 N (Current carrying capacity / derating curves) | Test passed |
| Polarization when inserted requirement >20 N (Current carrying capacity / derating curves) | Test passed |
| Conductor cross section / conductor type / tensile force (Termination and connection method) | 0.2 mm² / solid / > 10 N |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (Electrical parameters) | 0.25 mm² ... 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve (Electrical parameters) | 0.25 mm² ... 1.5 mm² |