Key Specifications
Item:Specifications
Weight:Net weight: 300 g approx.
Details:Controller
Product:Ultra High-speed Laser Displacement Sensor [CCD Style]
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
WeightNet weight: 300 g approx.
DetailsController
ProductUltra High-speed Laser Displacement Sensor [CCD Style]
Accessory-
Part NumberHL-C1C-M
Alarm outputPhoto-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between alarm output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Cable lengthPower line: Less than 10 m 32.808 ftSignal line: Less than 30 m 98.425 ft
Product nameUltra High-speed Laser Displacement Sensor HL-C1(Discontinued)
Sampling rateSelectable from 100 micro s / 144 micro s / 200 micro s / 255 micro s / 332 micro s / 498 micro s / 1,000 micro s
Hold functionsSelectable from NORMAL / P-P / PEAK / VALLEY(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Product NumberHL-C1C-M
Supply voltage24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Digital filtersHigh pass: OFF, 10 to 2,000 Hz (9 steps)Low pass: OFF, 10 to 2,000 Hz (9 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Indicators : DARKRed LED (lights up upon disabled measurement due to insufficient light at sensor head 1 or 2)
Zero set ON inputZero set: ON when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Calibration : Span0.9000 to 1.1000(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Zero set OFF inputZero set: OFF when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Calibration : Shiftplus or minus 20.0000 mm plus or minus 0.787 in(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Current consumptionWhen 1 sensor is connected: 430 mA approx.When 2 sensors are connected: 550 mA approx.
Indicators : BRIGHTRed LED (lights up upon disabled measurement due to excessive light at sensor head 1 or 2)
Calculation functionsL plus or minus KA, L plus or minus KB, L plus or minus K (A plus or minus B)A, B: Sensor head 1, Sensor head 2 measurement values, L = plus or minus 999.9999, K = 0.0001 to 99.9999(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Serial input / outputRS-232C
Connectale sensor headMaximum 2 sensor heads
Analog output : CurrentOutput current: 4 to 20 mA/F.S. [default setting when diffuse reflective mode is selected (Note 2)]Output range: 0 to 29.5 mA (maximum of 25 mA at max. load impedance)Load impedance: 250 Ohm or less(Note 1) The maximum analog output current will vary with load impedance.(Note 2) If specular reflective mode is selected, then the default setting is 5.6 to 18.4 mA/F.S.
Analog output : VoltageOutput voltage: plus or minus 5 V/F.S. [default setting when diffuse reflective mode is selected (Note) ]Output range: -10.9 to +10.9 VOutput current: Max. 2 mA, Output impedance: 50 Ohm(Note) If specular reflective mode is selected, then the default setting is plus or minus 4 V/F.S.
Average number of samplesOFF, 2 to 32,768 times (16 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Judgment outputs (O1, O2)Photo-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between judgment output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Indicators : Laser emissionGreen LED (lights up during laser emission from sensor head 1 or sensor head 2, or immediately before laser emission)
Temprerature characteristicsplus or minus 0.01 % F.S./degrees
Timing input (Laser emission)Laser emission stops or continues when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input or there is an open circuit: determined based on input mode selection.
Alarm output : Output operationOpened when the amount of light is excessive or insufficient.
Alarm output : Short-circuit protectionIncorporated
Environmental resistance : Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Environmental resistance : Shock resistance196 m/s2 (20 G approx.) in X, Y and Z directions for 3 times each
Judgment outputs (O1, O2) : Output operationOpened or closed when the threshold value is reached. Determined based on judgment output mode selection. (The threshold value varies with the hysteresis setting.)
Environmental resistance : Ambient temperature0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Environmental resistance : Vibration resistance10 to 55 Hz frequency (period: 1 min.) 0.75 mm 0.030 in amplitude in X,Y and Z directions for 30 min. each
Judgment outputs (O1, O2) : Utilization categoryDC-12 or DC-13
Judgment outputs (O1, O2) : Short-circuit protectionIncorporated