Service time: Monday to Friday 9:00-18:00
HDFK 10I-HV NZ.A5E00913053 - HDFK 10I-HV NZ.A5E00913053 0717827 PHOENIX CONTACT PCB terminal block
In Stock Hot Product

HDFK 10I-HV NZ.A5E00913053

HDFK 10I-HV NZ.A5E00913053 0717827 PHOENIX CONTACT PCB terminal block

$0.00USD
4427 in stock
Key Specifications
:• Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data.
Note:WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Pitch:10.1 mm
Result:Test passed
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
• Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data.
NoteWEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Pitch10.1 mm
ResultTest passed
Color ()()
Amplitude0.35 mm (10 Hz ... 60.1 Hz)
Frequency10 - 150 - 10 Hz
Safety note• Only electrically qualified personnel may install and operate the product.To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering.
Sweep speed1 octave/min
Temperature960 °C
Acceleration5g (60.1 Hz ... 150 Hz)
Product typePanel feed-through terminal block
SpecificationIEC 60947-7-1:2009-04
Product familyHDFK 10-HV
Test directionsX-, Y- and Z-axis
Article revision01
Connector systemHDFK 10
Contact materialCu alloy
Stripping length10 mm
Time of exposure30 s
Connection methodScrew connection with tension sleeve
Tightening torque1.5 Nm ... 1.8 Nm
Nominal current IN57 A
Nominal voltage UN1000 V
Dimensional drawing
Insulating materialPA
Number of positions2
Nominal cross section10 mm²
Rated voltage (III/3)1000 V
Test duration per axis2.5 h
Surface characteristicstin-plated
Insulating material groupI
Internal cylindrical gageB6
CTI according to IEC 60112600
Rated surge voltage (III/3)8 kV
Conductor cross section rigid0.5 mm² ... 16 mm²
Ambient temperature (assembly)-5 °C ... 100 °C
Ambient temperature (operation)-40 °C ... 100 °C (Depending on the current carrying capacity/derating curve)
Conductor cross section flexible0.5 mm² ... 10 mm²
Rated insulation voltage (III/3)1000 V
Requirement temperature-rise testIncrease in temperature ≤ 45 K
minimum creepage distance (III/3)12.5 mm
Relative humidity (storage/transport)30 % ... 70 %
Flammability rating according to UL 94V0
Ambient temperature (storage/transport)-40 °C ... 70 °C
Comparative tracking index (IEC 60112)CTI 600
2 conductors with same cross section, solid0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible0.5 mm² ... 4 mm²
minimum clearance value - non-homogenous field (III/3)8 mm
Connection direction of the conductor to plug-in direction0 °
Glow wire flammability index GWFI according to EN 60695-2-12850
Glow wire ignition temperature GWIT according to EN 60695-2-13775
Temperature for the ball pressure test according to EN 60695-10-2125 °C
Conductor cross section, flexible, with ferrule, with plastic sleeve0.5 mm² ... 10 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.5 mm² ... 10 mm²
Conductor cross section/conductor type/tractive force setpoint/actual value0.5 mm² / solid / > 20 N
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.5 mm² ... 2.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 6 mm²

Product Description

Borne grommets, connection type: Screw connection with traction capsule, Screw connection with traction capsule, number of poles: 2, charging current: 57 A, section: 0.5 mm² - 16 mm², conductor connec
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top