| Parameter | Value |
|---|---|
| NS 35/15 | |
| note | The use of surge protection plugs reduces the load current of the terminal block (see technical data for CLT surge protection plugs). |
| Color | grey |
| Depth | 35.3 mm |
| width | 72.6 mm |
| Result | Test passed |
| height | 75.9 mm |
| Spectrum | Electrical Life Check Category 1, Class B, Body Mounted |
| ASD Level | 0.964 (m/s²)²/Hz |
| Frequency | f1= 5 Hz a f2= 150 Hz |
| Shock Form | Semi-sinusoidal |
| Acceleration | 0.58g |
| No. of poles | 10 |
| Product Type | Feed-through clamp |
| General notes | for surge protection CLIXTRAB suitable for the HCC 4 series |
| Mounting type | NS 35/7.5 |
| Shock Duration | 30 ms |
| Nominal voltage | 400 V |
| Test Directions | X, Y, and Z axis |
| Test Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Degree of pollution | 2 |
| Insulation material | PA |
| Overvoltage Category | Iii |
| Number of connections | 10 |
| Sizing Impulse Voltage | 4 kV |
| Test duration per axle | 5 h |
| Insulation Material Group | The |
| Standard-compliant connection | IEC 61984 |
| Ambient temperature (mounting) | -5 °C ... 70 °C |
| Number of connections per plan | 10 |
| Number of shocks per direction | 3 |
| Ambient temperature (operating) | -60 °C (for maximum operating temperature see derating curve) |
| Ambient Temperature (Activation) | -5 °C ... 70 °C |
| NFPA 130 Fume Toxicity (SMP 800C) | Exceeded |
| Cold static insulation material insert | -60 °C |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for short duration, no longer than 24 h, -60 °C °C to +70 °C) |
| Combustibility class according to UL 94 | V0 |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Surface Flammability NFPA 130 (ASTM E 162) | Exceeded |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| NFPA 130 (ASTM E 662) Specific Optical Density of Fumes | Exceeded |
| Insulation Material Relative Temperature Index (Elec., UL 746 B) | 130 °C |
Technical specifications and performance data