| Parameter | Value |
|---|---|
| 11 mm (for 10 mm²) | |
| Type | D7 |
| Tests | DIN VDE 0627/86 |
| Width | 21 mm |
| Height | 34.8 mm |
| Length | 21 mm |
| Series | HC-HS |
| General | for HC-STA-D07 housing, CK 4,0 crimp contacts |
| Application | Power |
| Product type | Contact insert with a fixed no. of positions |
| Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
| Rated current | 40 A |
| Article revision | 04 |
| Contact diameter | 4 mm |
| Contact material | Copper alloy |
| Contact numbering | 1 - 4 |
| Tightening torque | 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) |
| Connection profile | 4 |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 4 |
| Rated surge voltage | 8 kV |
| Overvoltage category | III |
| Connection technology | Crimp connection |
| Contact material type | turned |
| Rated voltage (III/3) | 830 V |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Conductor cross section | 1.5 mm² ... 6 mm² |
| Contact carrier material | PC |
| Contact surface material | Ag |
| Insertion/withdrawal cycles | ≥ 500 |
| Connection cross section AWG | 16 ... 10 |
| Ambient temperature (operation) | -40 °C ... 125 °C (including heating up of contacts) |
| Connection in acc. with standard | IEC / EN |
| Number of connections per position | 1 |
| Constructional and testing regulations | DIN VDE 0627/86 |
| Flammability rating according to UL 94 | V0 |
| Stripping length of the individual wire | 9 mm (1.5 ... 6.0 mm²) |
Technical specifications and performance data