| Parameter | Value |
|---|---|
| Assembly procedure:- Strip wire 9.5 mm,- connect the stripped part of the wire through the locking sleeve (for wire diameter > 3.2 mm),- crimp wire (with protracted locking sleeve) with CK2.5...ED crimp contact,- lock the locking sleeve with the crimp contact together with the module's insulating body. | |
| Width | 34.1 mm |
| Height | 61.3 mm |
| Length | 29.3 mm |
| Series | HC-M-HV |
| General | For HEAVYCON housing type B6 to B48, HC-M-B...MF-... hinged module carrier frame required, CK2,5-ED... imp contacts, crimp contacts not supplied as standard. |
| Application | High-voltage |
| Product type | Modular contact insert |
| Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
| Rated current | 16 A |
| Article revision | 04 |
| Contact diameter | 2.5 mm |
| Contact material | Copper alloy |
| Contact numbering | I, II |
| Connection profile | 2 |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 2 |
| Rated surge voltage | 15 kV |
| Overvoltage category | III |
| Connection technology | Crimp connection |
| Contact material type | turned |
| No. of power contacts | 2 |
| Rated voltage (III/3) | 2900 V (Conductor-PE) |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Minimum housing height | 72 mm |
| Number of module slots | 2 |
| Conductor cross section | 0.5 mm² ... 4 mm² |
| No. of control contacts | 0 |
| Contact carrier material | PC |
| Contact surface material | Ag (alternatively Au) |
| Insertion/withdrawal cycles | ≥ 500 |
| Connection cross section AWG | 20 ... 12 |
| Ambient temperature (operation) | -40 °C ... 125 °C |
| Rated voltage for power contacts | 2900/5000 V |
| Flammability rating according to UL 94 | V0 |
| Stripping length of the individual wire | 9.5 mm |
Technical specifications and performance data