HC-M-02-AT-M-25 - HC-M-02-AT-M-25 1421377 PHOENIX CONTACT Module inserts contact HC-M-02-AT-M-25 1421377
In Stock Hot Product

HC-M-02-AT-M-25

HC-M-02-AT-M-25 1421377 PHOENIX CONTACT Module inserts contact HC-M-02-AT-M-25 1421377

$0.00USD
3215 in stock
Key Specifications
:Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
General:For HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
Application:Power
Rated current:100 A
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
GeneralFor HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
ApplicationPower
Rated current100 A
Degree of pollution3
Number of positions2
Rated surge voltage8 kV
Overvoltage categoryIII
Assembly instructionsTo ensure correct use, installation in housing with IP54 protection or better is required
Rated voltage (III/3)1000 V
Flammability rating according to UL 94V0
Stripping length of the individual wire13 mm

Product Description

Contact insert module, Pin, Axial screw connection, 1000 V, 100 A, 10 mm2 ... 25 mm2, application: Power