| Parameter | Value |
|---|---|
| GTIN | 4055626112626 |
| Orderkey | 1417381 |
| Catalog page | Page 563 (C-2-2017) |
| Packing unit | 2 pc |
| Country of origin | PL (Poland) |
| Custom tariff number | 85366990 |
| (Ambient conditions) | 16 mm (40 mm²) |
| Minimum order quantity | 2 pc |
| Contact material (General) | Copper alloy |
| Rated current (Dimensions) | 200 A |
| Width (Key Commercial Data) | 34.2 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 54.5 mm |
| Length (Key Commercial Data) | 29.4 mm |
| (Mechanical characteristics) | The axial screw connection must be established using a 5 mm Allen key (for stranded conductors only) |
| Connection profile (Dimensions) | 1 |
| Rated surge voltage (Dimensions) | 8 kV |
| Note (Mechanical characteristics) | For HEAVYCON HC-B6 to B48 housing (housing height: min. 72 mm), HC-M-B..-MF-... module carrier frame required, axial connection for 5 mm Allen key |
| Color (Mechanical characteristics) | light gray |
| Contact carrier material (General) | PC |
| Contact surface material (General) | Ag |
| Rated voltage (III/3) (Dimensions) | 1000 V |
| Series (Mechanical characteristics) | HC-M-HS |
| Weight per Piece (excluding packing) | 63.800 g |
| Contact diameter (Ambient conditions) | 9.5 mm |
| Hexagonal socket (Ambient conditions) | WAF 5 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Tightening torque (Ambient conditions) | 8 Nm (25 mm² ... 35 mm²) |
| Connection (Mechanical characteristics) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. |
| Contact type (Mechanical characteristics) | turned |
| Minimum housing height (Ambient conditions) | 72 mm |
| Conductor cross section (Ambient conditions) | 25 mm² ... 70 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Connection method (Mechanical characteristics) | Axial screw connection |
| Degree of pollution (Mechanical characteristics) | 3 |
| Insertion/withdrawal cycles (Ambient conditions) | ≥ 500 |
| Connection cross section AWG (Ambient conditions) | 10 ... |
| Overvoltage category (Mechanical characteristics) | III |
| Assembly instructions (Mechanical characteristics) | To ensure correct use, installation in housing with IP54 protection or better is required |
| Number of module slots (Mechanical characteristics) | 2 |
| Flammability rating according to UL 94 (Material data) | V0 |
| Wire diameter including insulation (Ambient conditions) | 12 mm (25 mm²) |
| Ambient temperature (operation) (Electrical characteristics) | -40 °C ... 125 °C |
| Stripping length of the individual wire (Ambient conditions) | 16 mm |
| Flammability rating according to UL 94 (Mechanical characteristics) | V0 |
Technical specifications and performance data
Installation and operation guide