HC-HS 2-D7-ESTS - HC-HS 2-D7-ESTS 1586277 PHOENIX CONTACT Contact insert
In Stock Hot Product

HC-HS 2-D7-ESTS

HC-HS 2-D7-ESTS 1586277 PHOENIX CONTACT Contact insert

$31.75USD
358 in stock
Key Specifications
GTIN:4046356410229
Note:Made to Order (non-returnable)
Orderkey:1586277
Catalog page:Page 507 (C-2-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356410229
NoteMade to Order (non-returnable)
Orderkey1586277
Catalog pagePage 507 (C-2-2017)
Packing unit10 pc
Country of originDE (Germany)
Custom tariff number85366990
(Key Commercial Data)The axial screw connection must be established using a 2 mm Allen key (for stranded conductors only)
Minimum order quantity10 pc
Size (Key Commercial Data)D7
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
(Electrical characteristics)IEC 60352
Rated current (Material data)40 A
Connection (Key Commercial Data)Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Rated surge voltage (Material data)6 kV
Weight per Piece (excluding packing)23.410 g
Contact material (Ambient conditions)Copper alloy
Rated voltage (III/3) (Material data)400 V
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Connection method (Key Commercial Data)Axial screw connection
Contact numbering (Key Commercial Data)1 - 2
Tightening torque (Key Commercial Data)1.8 Nm
Ambient temperature (operation) (General)-40 °C ... 125 °C (including heating up of contacts)
Degree of pollution (Key Commercial Data)3
Number of positions (Key Commercial Data)2+PE
Overvoltage category (Key Commercial Data)III
Assembly instructions (Key Commercial Data)To ensure correct use, installation in housing with IP54 protection or better is required
Conductor cross section (Key Commercial Data)4 mm² ... 10 mm²
Contact carrier material (Ambient conditions)PC
Contact surface material (Ambient conditions)Ag
Insertion/withdrawal cycles (Key Commercial Data)≥ 500
Connection cross section AWG (Key Commercial Data)10 ... 8
Connection in acc. with standard (Electrical characteristics)CUL
Stripping length of the individual wire (Key Commercial Data)8 mm +1
Constructional and testing regulations (Electrical characteristics)DIN VDE 0627/86
Flammability rating according to UL 94 (Electrical characteristics)V0

Product Description

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Male, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty