| Parameter | Value |
|---|---|
| B48 | |
| Type | B24 |
| Tests | DIN EN 61984 |
| Width | 34 mm |
| Height | 34.6 mm |
| Length | 111 mm |
| Series | HC-B |
| General | Use only flexible conductors with ferrule (in conjunction with CRIMPFOX 6 only) |
| Application | Power |
| Product type | Contact insert with a fixed no. of positions |
| Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
| Rated current | 16 A |
| Article revision | 03 |
| Contact diameter | 2.5 mm |
| Contact material | Copper alloy |
| Contact numbering | 1 - 24 |
| Tightening torque | 0.8 Nm ... 1.2 Nm (PE connection) |
| Connection profile | 24+PE |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 24 |
| Rated surge voltage | 6 kV |
| Overvoltage category | III |
| Connection technology | Push-in connection |
| Rated voltage (III/3) | 500 V |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Conductor cross section | 0.25 mm² ... 1.5 mm² |
| Contact carrier material | PC |
| Contact surface material | Ag |
| Insertion/withdrawal cycles | ≥ 500 |
| Connection cross section AWG | 24 ... 16 |
| Ambient temperature (operation) | -40 °C ... 125 °C |
| Drill hole distance, horizontal | 104 mm |
| Number of connections per position | 2 |
| Constructional and testing regulations | DIN EN 61984 |
| Flammability rating according to UL 94 | V0 |
| Stripping length of the individual wire | 8 mm ±1 mm |
Technical specifications and performance data