| Parameter | Value |
|---|---|
| GTIN | 4046356156141 |
| Orderkey | 1584936 |
| Catalog page | Page 541 (C-2-2017) |
| Packing unit | 1 pc |
| Country of origin | CN (China) |
| Custom tariff number | 85366990 |
| (Key Commercial Data) | Connectors may be operated only when there is no load/voltage. |
| Note (Key Commercial Data) | For HEAVYCON-ADVANCE of B24 type and HEAVYCON housing of B24/B48 type Plug-in connections may only be operated only when there is no load/voltage. |
| Size (Key Commercial Data) | B24 |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| (Electrical characteristics) | IEC 60352 |
| Rated current (Material data) | 20 A |
| Connection (Key Commercial Data) | Connectors may only be actuated when there is no load/voltage. |
| Rated surge voltage (Material data) | 6 kV |
| Weight per Piece (excluding packing) | 111.500 g |
| Contact material (Ambient conditions) | Copper alloy |
| Rated voltage (III/3) (Material data) | 500 V |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Connection method (Key Commercial Data) | Screw connection |
| Contact numbering (Key Commercial Data) | 25 - 48 |
| Screwdriver blade (Key Commercial Data) | 0.5 x 3.5 mm |
| Tightening torque (Key Commercial Data) | 0.5 Nm ... 0.8 Nm |
| Ambient temperature (operation) (General) | -40 °C ... 125 °C (including heating up of contacts) |
| Degree of pollution (Key Commercial Data) | 3 |
| Number of positions (Key Commercial Data) | 24+PE |
| Overvoltage category (Key Commercial Data) | III |
| Assembly instructions (Key Commercial Data) | To ensure correct use, installation in housing with IP54 protection or better is required |
| Conductor cross section (Key Commercial Data) | 0.5 mm² ... 2.5 mm² (applies to stranded conductors with ferrules) |
| Contact carrier material (Ambient conditions) | PC |
| Contact surface material (Ambient conditions) | Ag |
| Insertion/withdrawal cycles (Key Commercial Data) | ≥ 500 |
| Connection cross section AWG (Key Commercial Data) | 20 ... 14 |
| Connection in acc. with standard (Electrical characteristics) | CSA |
| Stripping length of the individual wire (Key Commercial Data) | 8 mm |
| Constructional and testing regulations (Electrical characteristics) | DIN EN 61984 |
| Flammability rating according to UL 94 (Electrical characteristics) | V0 |
Technical specifications and performance data