| Parameter | Value |
|---|---|
| 61.4 Years (Telcordia standard, 40°C temperature, 50% stress, Environmental Factor = 1.5) | |
| ATEX | DEMKO 18ATEX 2026X: II 3 GEx ec IIC T4 Gc |
| MTBF | 92.1 Years (Telcordia standard, 25°C temperature, 50% stress, Environmental Factor = 1.0) |
| Color | gray |
| Depth | 115 mm |
| IECEx | IECEx UL 18.0023XEx ec IIC T4 Gc |
| Width | 22.5 mm |
| Height | 99 mm |
| Signal | Ethernet |
| UL, USA | UL 61010-1 |
| Altitude | < 2000 m |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
| Management | Web-based management |
| Web server | yes |
| Conformance | CE-compliant |
| Product type | Interface converter |
| Mounting type | DIN rail mounting |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2:2005 |
| Pin assignment | DTE |
| No. of channels | 1 |
| Article revision | 04 |
| Housing material | PA 6.6 |
| UL, USA / Canada | Class I, Div. 2, Groups A, B, C, D T4A |
| Connection method | RJ45 jack, shielded |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| File format/coding | 5/6/7/8 Data bits, 1/2 Stop bits, None/Even/Odd/Mark/Space Parity |
| Auxiliary protocols | ARP, DHCP (Client), PING |
| Note on application | Only for industrial use |
| Protocols supported | PROFINET, ASCII |
| Transmission length | ≤ 100 m (shielded twisted pair) |
| Degree of protection | IP20 |
| Electrical isolation | IEC UL 61010-1 (VCC // Ethernet) |
| Supply voltage range | 10.8 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
| Termination resistor | 120 Ω (configurable) |
| Number of connections | 1 |
| Standards/regulations | EN 55022, EN 55024 |
| Max. current consumption | 60 mA (24 V DC) |
| Serial transmission speed | 10/100 Mbps, auto negotiation |
| Conductor cross section AWG | 24 ... 12 |
| Data flow control/protocols | Software handshake, Xon/Xoff or hardware handshake RTS/CTS |
| Typical current consumption | 48 mA (24 V DC) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Status and diagnostic indicators | LEDs: Status, ACT/LNK (Ethernet data traffic) |
| Conductor cross section, flexible | 0.20 mm² ... 2.50 mm² |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
| Test voltage data interface/data interface | 1.5 kVrms(50 Hz, 1 min.) |
Technical specifications and performance data
Installation and operation guide