| Parameter | Value |
|---|---|
| 0.2 mm² / flexible / > 10 N | |
| Link | Screw connection with cage |
| Step | 7.62 mm |
| note | Complies with WEEE/RoHS, no thread-like materials according to IEC 60068-2-82/JEDEC JESD 201 |
| type | Standard |
| Result | Test passed |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Frequency | 10 - 150 - 10 Hz |
| Packaging | Packed in carton |
| Width [w] | 33.25 mm |
| Height [h] | 15 mm |
| Length [l] | 18.2 mm |
| Shock Form | Semi-sinusoidal |
| Sweep Speed | 1 octave/min |
| Acceleration | 5g (60.1 Hz ... 150 Hz) |
| Color (Case) | Green (6021) |
| Product Line | COMBICON Connectors M |
| Product Type | Printed circuit board connector |
| Clamping Type | Screw locking |
| Fixing flange | Screw flange |
| Article review | 02 |
| Number of rows | 1 |
| Product Family | GMSTB 2.5/.. -STF |
| Shock Duration | 18 ms |
| Surface Finish | Hot-dip galvanizing |
| Number of poles | 3 |
| Test Directions | X, Y, and Z axis |
| Connector system | COMBICON MSTB 2.5 |
| Contact Material | Cu Alloy |
| Fixed AC voltage | 3.31 kV |
| Mass Resistivity | 1.2 mΩ |
| Number of cycles | 25 |
| Rated Current IN | 12 A |
| Rated voltage UN | 630 V |
| Tightening torque | 0.3 Nm |
| Manoeuvring cycles | 25 |
| Note for Operation | According to DIN EN 61984, COMBICON connectors are connectors without switchable power (COC). For use in accordance with the intended use, they must not be switched on or disconnected while they are still live or under load. |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Dimensioned Drawing | |
| Insulation material | PA |
| Mass Resistivity R1 | 1.2 mΩ |
| Mass Resistivity R2 | 1.3 mΩ |
| Nominal cross-section | 2.5 mm² |
| Sizing voltage (II/2) | 1000 V |
| Number of poles tested | 12 |
| Sizing voltage (III/2) | 630 V |
| Sizing voltage (III/3) | 400 V |
| Test duration per axle | 2.5 h |
| Contact Connection Type | female |
| Stress due to corrosion | 0.2 dm3KNOW2on 300 dm3/40 °C/1 cycle |
| Appliance type screw head | Longitudinal slit (L) |
| Insulation Material Group | The |
| Recommended crimping tool | 1212034 CRIMPFOX 6 |
| CTI according to IEC 60112 | 600 |
| Conductor cross-section AWG | 24 ... 12 |
| Rated Impulse Voltage (II/2) | 6 kV |
| Buffer Gauge a x b / diameter | 2.8 mm x 2.0 mm / 2.4 mm |
| Minimum creepage value (II/2) | 5.5 mm |
| Rated impulse voltage (III/2) | 6 kV |
| Rated impulse voltage (III/3) | 6 kV |
| Rigid conductor cross-section | 0.2 mm² ... 2.5 mm² |
| Sizing Impulse Voltage (II/2) | 6 kV |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Minimum creepage value (III/2) | 5.5 mm |
| Minimum creepage value (III/3) | 5.5 mm |
| Note on the Connection Section | In the case of a conductor connected by 2.5 mm² (flexible). |
| Rated Isolation Voltage (II/2) | 1000 V |
| Sizing Impulse Voltage (III/2) | 6 kV |
| Sizing impulse voltage (III/3) | 6 kV |
| Tensile force per pole approx. | 6 N |
| Ambient temperature (operating) | -40 °C ... 105 °C (depending on the derating curve) |
| Rated Isolation Voltage (III/2) | 630 V |
| Flexible conductor cross-section | 0.2 mm² ... 2.5 mm² |
| Insertion force per pole approx. | 8 N |
| Rated insulation voltage (III/3) | 400 V |
| Stress due to the effect of heat | 105 °C/168 h |
| Conductor/board connection direction | 0 ° |
| Length of the section to be stripped | 7 mm |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Combustibility class according to UL 94 | V0 |
| Vertical impulse tension above sea level | 7.3 kV |
| Relative humidity (transport and storage) | 30 % ... 70 % |
| Metal surface contact zone (surface layer) | Tin (5 - 7 μm Sn) |
| 2 conductors of identical cross-section, rigid | 0.2 mm² ... 1 mm² |
| Insulation Resistance Between Contiguous Poles | > 5 MΩ |
| Metal Surface, Connection Point (Surface Layer) | Tin (5 - 7 μm Sn) |
| 2 conductors of identical flexible cross-section | 0.2 mm² ... 1.5 mm² |
| Minimum creepage value - inhomogeneous range (II/2) | 5.5 mm |
| Minimum creepage value - inhomogeneous range (III/2) | 5.5 mm |
| Minimum clearance value - inhomogeneous range (III/3) | 5.5 mm |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Brinell hardness test temperature according to EN 60695-10-2 | 125 °C |
| GWIT filament ignition temperature according to EN 60695-2-13 | 775 |
| Flammability index of GWFI filament according to EN 60695-2-12 | 850 |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.25 mm² ... 2.5 mm² |
| Flexible conductor cross-section with cable lug without plastic collar | 0.25 mm² ... 2.5 mm² |
| Conductor cross-section/conductor type/tensile force nominal value/actual value | 0.2 mm² / rigid / > 10 N |
| 2 conductors of the same flexible cross-section with ferrule without plastic collar | 0.25 mm² ... 1 mm² |
| 2 conductors of identical cross-section flexible with TWIN ferrule with plastic collar | 0.5 mm² ... 1 mm² |
Technical specifications and performance data