Key Specifications
Weight (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.):Approx. 400 g
2 to 35 A (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.):100×55×137
Order code (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.):G3PF-225B
Alarm output (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.):Output ON voltage drop
Supplier Information
OMRON
OMRON
Products: 41472
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Weight (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)Approx. 400 g
2 to 35 A (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)100×55×137
Order code (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)G3PF-225B
Alarm output (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)Output ON voltage drop
Main circuit (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)Output ON voltage drop
Operate time (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)1/2 of load power source cycle + 1 ms max.
Release time (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)1/2 of load power source cycle + 1 ms max.
100 to 240 VAC (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)2 to 25 A
200 to 480 VAC (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)2 to 25 A
Leakage current (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)1 mA max.
Shock resistance (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)Destruction: 294 m/s²
Rated load voltage (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)100 to 240 VAC (50/60 Hz)
Dielectric strength (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)2,500 VAC, 50/60 Hz for 1 min.
Isolation resistance (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)100 MΩ min. (at 500 VDC)
Minimum load current (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)2 A
Vibration resistance (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)Destruction: 10 to 55 to10 Hz, 0,35-mm single amplitude (0,7-mm double amplitude)
Applicable output load1 (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)Input terminals
Operating voltage range (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)75 to 264 VAC, 50/60 Hz
Applicable load current2 (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)25 A (at 40°C)
Inrush current resistance (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)220 A (60 Hz, 1 cycle)
Ambient operating humidity (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)45% to 85%
Ambient storage temperature (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)−30 to 70°C (with no icing or condensation)
Ambient operating temperature (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.)−20 to 60°C (with no icing or condensation)

Product Description

35A 200-480VAC 2 Outputs Removable Screw Connector
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

The G3PF quickly detects heater burnout and SSR short-circuit failure, and information is provided to let you know which problem has occurred, which is ideal for applications where down time must be minimized.

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top