| Parameter | Value |
|---|---|
| Weight (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | Approx. 400 g |
| 2 to 35 A (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 100×55×137 |
| Order code (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | G3PF-225B |
| Alarm output (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | Output ON voltage drop |
| Main circuit (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | Output ON voltage drop |
| Operate time (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 1/2 of load power source cycle + 1 ms max. |
| Release time (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 1/2 of load power source cycle + 1 ms max. |
| 100 to 240 VAC (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 2 to 25 A |
| 200 to 480 VAC (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 2 to 25 A |
| Leakage current (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 1 mA max. |
| Shock resistance (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | Destruction: 294 m/s² |
| Rated load voltage (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 100 to 240 VAC (50/60 Hz) |
| Dielectric strength (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 2,500 VAC, 50/60 Hz for 1 min. |
| Isolation resistance (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 100 MΩ min. (at 500 VDC) |
| Minimum load current (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 2 A |
| Vibration resistance (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | Destruction: 10 to 55 to10 Hz, 0,35-mm single amplitude (0,7-mm double amplitude) |
| Applicable output load1 (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | Input terminals |
| Operating voltage range (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 75 to 264 VAC, 50/60 Hz |
| Applicable load current2 (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 25 A (at 40°C) |
| Inrush current resistance (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 220 A (60 Hz, 1 cycle) |
| Ambient operating humidity (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | 45% to 85% |
| Ambient storage temperature (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | −30 to 70°C (with no icing or condensation) |
| Ambient operating temperature (“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.) | −20 to 60°C (with no icing or condensation) |
Technical specifications and performance data
Installation and operation guide