| Parameter | Value |
|---|---|
| 1 (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 100 to 240 VAC(75 to 264 VAC) |
| 2 (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | G3PE-515B-2N DC12-24 |
| 3 (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 200 to 480 VAC(180 to 528 VAC) |
| 35 A (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 1,260 A2s |
| 45 A (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 37.4 kW (at 480 VAC) |
| Phases (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | Rated voltage(operating voltage) |
| 100×80×155 (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 2 |
| 120×80×155 (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 2 |
| 140×80×155 (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 2 |
| Operate time (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 1/2 of load power source cycle +1 ms max. |
| Release time (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 1/2 of load power source cycle +1 ms max. |
| 25 A (at 40°C) (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 20.7 kW (at 480 VAC) |
| Leakage current (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 10 mA (at 200 VAC) |
| Isolation method (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | Phototriac coupler |
| Load voltage range (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 200 to 480 VAC models: 180 to 528 VAC100 to 240 VAC models: 75 to 264 VAC |
| Ambient temperature (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | Operating: -30 to 80°C |
| Operation indicator (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | Yes (yellow) |
| Rated input voltage (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 12 to 24 VDC |
| Zero cross function (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | Yes |
| Must operate voltage (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 9.6 VDC max. |
| Must release voltage (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 1 VDC min. |
| Operating voltage range (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 9.6 to 30 VDC |
| 200 to 480 VAC(180 to 528 VAC) (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 15 A (at 40°C) |
| Rated input current (impedance) (Omron’s G3PE Compact Industrial SSR with outstanding surge endurance) | 7 mA max. (zero cross models); 15 mA max. (models without zero cross) |
Technical specifications and performance data
Installation and operation guide