| Parameter | Value |
|---|---|
| Item | Specifications |
| Details | Heat-resistant Fiber |
| Product | Thru-beam type Fiber |
| Free-cut | Available |
| Fiber type | Heat-resistant (joint) |
| Application | Heat-resistant |
| Part Number | FT-H20-J30-S |
| With sleeve | No |
| Product name | Heat-resistant Fiber |
| Sensing mode | Thru-beam type |
| Mounting lens | Available |
| Beam direction | Top-view |
| Product Number | FT-H20-J30-S |
| Applicable lens | FX-LE1,FX-LE2,FX-SV1 |
| Fiber head dia. | M4 |
| Fiber head length | 23 mm |
| Fiber cable length | 300 mm(Note) Fiber length (fixed-length) for heat-resistant fiber side. Fiber length for ordinary temperature side is 2 m 6.562 ft (free-cut) . |
| Sensing range(STD) | 470 mm 18.504 in (FX-500 series) |
| Sensing range(FAST) | 300 mm 11.811 in (FX-500 series) |
| Sensing range(H-SP) | 90 mm 3.543 in (FX-500 series) |
| Sensing range(HYPR) | 1,600 mm 62.992 in (FX-500 series) |
| Sensing range(LONG) | 790 mm 31.102 in (FX-500 series) |
| Sensing range(U-LG) | 1,000 mm 39.370 in (FX-500 series) |
| Allowable bending radius | Heatresistant side R18 mm(Note) Bending durable fiber R4 mm R0.157 in or more for ordinary temperature side. |
| Mounting protective tube | Not available |
| Beam axis dia./ Spot diameter | dia. 1.2 mm |
| Environmental resistance : Ambient temperature MAX | 200 degrees |
| Environmental resistance : Ambient temperature MIN | -60 degrees |