| Parameter | Value |
|---|---|
| GTIN | 4055626039091 |
| Note | Made to Order (non-returnable) |
| Orderkey | 3271075 |
| Packing unit | 50 pc |
| Width (General) | 6.2 mm |
| Height (General) | 35.3 mm |
| Length (General) | 77 mm |
| Country of origin | PL (Poland) |
| Custom tariff number | 85369010 |
| (Key Commercial Data) | Process industry |
| Minimum order quantity | 50 pc |
| End cover width (General) | 2.2 mm |
| Height NS 35/15 (General) | 44 mm |
| Height NS 35/7,5 (General) | 36.5 mm |
| Stripping length (General) | 10 mm ... 12 mm |
| Color (Key Commercial Data) | green-yellow |
| Connection method (General) | Push-in connection |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Open side panel (Dimensions) | Yes |
| Degree of pollution (Dimensions) | 3 |
| Rated surge voltage (Dimensions) | 8 kV |
| Overvoltage category (Dimensions) | III |
| Internal cylindrical gage (General) | A4 |
| Weight per Piece (excluding packing) | 16.230 g |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Insulating material group (Dimensions) | I |
| Number of levels (Key Commercial Data) | 1 |
| Area of application (Key Commercial Data) | Machine building |
| Insulating material (Key Commercial Data) | PA |
| Conductor cross section AWG max. (General) | 10 |
| Conductor cross section AWG min. (General) | 24 |
| Connection in acc. with standard (General) | IEC 60947-7-2 |
| NF F16-101, NF F10-102 Class F (Dimensions) | 2 |
| NF F16-101, NF F10-102 Class I (Dimensions) | 2 |
| Nominal cross section (Key Commercial Data) | 4 mm² |
| Number of connections (Key Commercial Data) | 4 |
| Conductor cross section solid max. (General) | 6 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Oxygen index (DIN EN ISO 4589-2) (Dimensions) | >32 % |
| Conductor cross section flexible max. (General) | 4 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Connection in acc. with standard (Connection data) | IEC 60947-7-2 |
| Flame test method (DIN EN 60695-11-10) (Dimensions) | V0 |
| Smoke gas toxicity NFPA 130 (SMP 800C) (Dimensions) | passed |
| Max. AWG conductor cross section, flexible (General) | 12 |
| Min. AWG conductor cross section, flexible (General) | 24 |
| Surface flammability NFPA 130 (ASTM E 162) (Dimensions) | passed |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Static insulating material application in cold (Dimensions) | -60 °C |
| Behavior in fire for rail vehicles (DIN 5510-2) (Dimensions) | Test passed |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) (Dimensions) | 28 MJ/kg |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 (Dimensions) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 (Dimensions) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 (Dimensions) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 (Dimensions) | HL 1 - HL 3 |
| Specific optical density of smoke NFPA 130 (ASTM E 662) (Dimensions) | passed |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data) | HL 1 - HL 3 |
| Relative insulation material temperature index (Elec., UL 746 B) (Dimensions) | 130 °C |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (General) | 4 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (General) | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (General) | 4 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (General) | 0.25 mm² |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Dimensions) | 130 °C |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (General) | 1 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (General) | 0.5 mm² |
Technical specifications and performance data
Installation and operation guide