| Parameter | Value |
|---|---|
| Step | 1.27 mm |
| Amplitude | 1.5 mm (10 Hz ... 58 Hz) |
| Width [w] | 19.05 mm |
| frequency | 10 - 2000 - 10 Hz |
| Height [h] | 14.55 mm |
| Length [l] | 5 mm |
| Shock Type | Semi-sinusoidal |
| Observation | WEEE/RoHS compliant, filament-free according to IEC 60068-2-82/JEDEC JESD 201 |
| Plug Cycles | 500 |
| Sweep speed | 1 octave/min |
| Acceleration | 490 m/s² |
| Product Type | IDC plug plug |
| Test voltage | 500 V AC IEC 60512-4-1:2003 |
| Locking system | Lace lock |
| Number of rows | 2 |
| Product Family | FR 1,27/.. -FWL |
| Clamping flange | Lace Flange |
| Color (Housing) | Black (9005) |
| Connection type | Scroll connection |
| Contact Coating | 0.9 mm |
| Number of poles | 20 |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Contact material | Cu Alloy |
| Angular Tolerance | ± 5° on longitudinal and transverse axis |
| Type of packaging | Tray |
| Contact resistance | 10 mΩ |
| Nominal Current IN | 1.4 A IEC 60512-5-2:2002-02 (at 20 °C 50 poles) |
| Outer packing type | Cardboard |
| Test Specification | IEC 60512-5-2:2002-02 |
| Degree of pollution | 3 |
| Insulating material | LCP |
| Shifting the Center | ± 0.7 mm on longitudinal and transverse axis |
| AWG Conductor Section | 30 |
| Contact Resistance R1 | 10 mΩ |
| Contact Resistance R2 | 12 mΩ |
| Duration of the crash | 11 ms |
| Note on documentation | Current documents such as 3D models, product family diagrams, data sheets or packaging diagrams are available in the Download Center. |
| Test duration per axis | 1 h |
| Surface Characteristics | Selective Coating |
| Insulating material group | IIIb |
| CTI according to IEC 60112 | 150 |
| Ambient Temperature (Service) | -55 °C ... 125 °C |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Metal surface weld area (top layer) | Tin (Sn) |
| Insulation Resistance Adjacent Poles | ≥ 5 GΩ |
| Flammability class according to UL 94 | V0 |
| Metal surface contact area (top layer) | Gold (Au) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Minimum air gap and creepage line value | 0.32 mm |
| Metal Surface Contact Area (Middle Layer) | Nickel (Ni) |
| Metal Surface Welding Area (Middle Layer) | Nickel (Ni) |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |